Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Illinois, Chicago |
---|---|
Assessment Year | 2011 |
Principal Product | Axles & Driveline Products |
NAICS | 336350 - Motor Vehicle Transmission and Power Train Parts Manufacturing |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $5,000,000-$10,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 610,000 |
Annual Production | 7,500 Pieces |
Production Hrs. Annual | 4,233 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $256,196 | 5,414,038 | kWh | $0.05 |
Electricity Demand | $79,019 | 10,188 | kW-months/year | $7.76 |
Electricity Fees | $32,483 | - | $ | - |
Natural Gas | $288,948 | 38,422 | MMBtu | $7.52 |
TOTAL ENERGY COSTS | $665,676 | |||
RECOMMENDED SAVINGS* | $176,979 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $176,685 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $2,166 Cost: - |
- | - | - | - | $2,166 | 288 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,166 288 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7233 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT |
Savings: $156,506 Cost: $686,583 |
- | - | - | - | $156,506 | 20,812 | - | - | - | - |
- - kWh |
- - kW-months/year |
$156,506 20,812 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $12,266 Cost: $100,000 |
- | - | - | - | $12,266 | 1,631 | - | - | - | - |
- - kWh |
- - kW-months/year |
$12,266 1,631 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,263 Cost: $1,142 |
$1,030 | 21,914 | $233 | 30 | - | - | - | - | - | - |
$1,030 21,914 kWh |
$233 30 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $4,441 Cost: $382 |
$4,441 | 94,494 | - | - | - | - | - | - | - | - |
$4,441 94,494 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $43 Cost: $58 |
$9 | 175 | $2 | 0 | - | - | $10 | - | $22 | - |
$9 175 kWh |
$2 0 kW-months/year |
- - MMBtu |
$10 - $ |
$22 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $294 Cost: - |
$240 | 5,100 | $54 | 7 | - | - | - | - | - | - |
$240 5,100 kWh |
$54 7 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $176,979 Cost: $788,165 |
$5,720 | 121,683 | $289 | 37 | $170,938 | 22,731 | $10 | - | $22 | - | $5,720 121,683 kWh |
$289 37 kW-months/year |
$170,938 22,731 MMBtu |
$10 - $ |
$22 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $176,685 Cost: $788,165 |
$5,480 | 116,583 | $235 | 30 | $170,938 | 22,731 | $10 | - | $22 | - | $5,480 116,583 kWh |
$235 30 kW-months/year |
$170,938 22,731 MMBtu |
$10 - $ |
$22 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost |