IAC logo
IAC Assessment: IC0219
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: IC0219
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Illinois, Chicago
Assessment Year 2019
Principal Product Vinyl Tile Flooring
NAICS 327110 - Pottery, Ceramics, and Plumbing Fixture Manufacturing
SIC 3269 - Pottery Products, Nec
Sales $5,000,000-$10,000,000
# of Employees 285
Plant Area (Sq.Ft.) 350,000
Annual Production 231 Thousand Feet
Production Hrs. Annual 6,240
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $2,568,583 44,748,598 kWh $0.06
Electricity Demand $593,440 96,756 kW-months/year $6.13
Electricity Fees $299,510 - $ -
Natural Gas $788,631 204,230 MMBtu $3.86
TOTAL ENERGY COSTS $4,250,165
RECOMMENDED SAVINGS* $101,567 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.1224 REPLACE BOILER Savings:
$68,168
Cost:
$25,600
- - - - $68,168 17,660 -
-
kWh
-
-
kW-months/year
$68,168
17,660
MMBtu
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$30,480
Cost:
$17,728
- - - - $30,480 7,897 -
-
kWh
-
-
kW-months/year
$30,480
7,897
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,919
Cost:
$737
$2,163 36,044 $756 119 - - $2,163
36,044
kWh
$756
119
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$101,567
Cost:
$44,065
$2,163 36,044 $756 119 $98,648 25,556 $2,163
36,044
kWh
$756
119
kW-months/year
$98,648
25,556
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas