Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Illinois, Chicago |
---|---|
Assessment Year | 2021 |
Principal Product | Cracker/Biscuit Products |
NAICS | 311821 - Cookie and Cracker Manufacturing |
SIC | 2052 - Cookies And Crackers |
Sales | $100,000,000-$500,000,000 |
# of Employees | 25 |
Plant Area (Sq.Ft.) | 500,000 |
Annual Production | 7,000,000 Units |
Production Hrs. Annual | 5,214 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $424,293 | 7,467,595 | kWh | $0.06 |
Electricity Demand | $116,588 | 15,819 | kW-months/year | $7.37 |
Electricity Fees | $139,393 | - | $ | - |
Natural Gas | $234,400 | 74,303 | MMBtu | $3.15 |
TOTAL ENERGY COSTS | $914,674 | |||
RECOMMENDED SAVINGS* | $25,971 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $18,421 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,735 Cost: $1,539 |
$5,958 | 104,520 | $1,778 | 241 | - | - |
$5,958 104,520 kWh |
$1,778 241 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $2,646 Cost: $64,258 |
$2,373 | 41,637 | $273 | 37 | - | - |
$2,373 41,637 kWh |
$273 37 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,752 Cost: $1,964 |
$2,352 | 41,257 | $1,400 | 190 | - | - |
$2,352 41,257 kWh |
$1,400 190 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $8,040 Cost: $5,000 |
$6,395 | 112,195 | $1,645 | 223 | - | - |
$6,395 112,195 kWh |
$1,645 223 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,246 Cost: $207 |
$989 | 17,348 | $257 | 35 | - | - |
$989 17,348 kWh |
$257 35 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4324 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT |
Savings: $283 Cost: $578 |
$222 | 3,906 | $61 | 8 | - | - |
$222 3,906 kWh |
$61 8 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,269 Cost: $24,850 |
- | - | - | - | $2,269 | 709 |
- - kWh |
- - kW-months/year |
$2,269 709 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $25,971 Cost: $98,396 |
$18,289 | 320,863 | $5,414 | 734 | $2,269 | 709 | $18,289 320,863 kWh |
$5,414 734 kW-months/year |
$2,269 709 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $18,421 Cost: $70,797 |
$14,726 | 258,352 | $3,696 | 501 | - | - | $14,726 258,352 kWh |
$3,696 501 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |