Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Illinois, Chicago |
---|---|
Assessment Year | 2023 |
Principal Product | Water Soluble Film |
NAICS | 326113 - Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing |
SIC | 3081 - Unsupported Plastics Film & Sheet |
Sales | $10,000,000-$50,000,000 |
# of Employees | 89 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 7,416,350 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $194,910 | 4,378,880 | kWh | $0.04 |
Electricity Demand | $214,964 | 8,059 | kW-months/year | $26.67 |
Electricity Fees | $127,049 | - | $ | - |
Natural Gas | $904,639 | 125,797 | MMBtu | $7.19 |
TOTAL ENERGY COSTS | $1,441,562 | |||
RECOMMENDED SAVINGS* | $507,372 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $125,865 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $36,114 Cost: $7,997 |
$2,238 | 49,732 | $33,876 | 1,270 | - | - |
$2,238 49,732 kWh |
$33,876 1,270 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $83,404 Cost: $10,984 |
- | - | - | - | $83,404 | 11,121 |
- - kWh |
- - kW-months/year |
$83,404 11,121 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $102,187 Cost: $5,165 |
- | - | - | - | $102,187 | 13,625 |
- - kWh |
- - kW-months/year |
$102,187 13,625 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $6,347 Cost: $3,405 |
- | - | - | - | $6,347 | 846 |
- - kWh |
- - kW-months/year |
$6,347 846 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,869 Cost: $2,547 |
- | - | - | - | $1,869 | 204 |
- - kWh |
- - kW-months/year |
$1,869 204 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $23,020 Cost: $4,424 |
- | - | - | - | $23,020 | 3,069 |
- - kWh |
- - kW-months/year |
$23,020 3,069 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $12,027 Cost: $90 |
- | - | - | - | $12,027 | 1,604 |
- - kWh |
- - kW-months/year |
$12,027 1,604 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $992 Cost: $1,773 |
$932 | 20,703 | $60 | 2 | - | - |
$932 20,703 kWh |
$60 2 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $85,492 Cost: $1,202,972 |
$64,237 | 1,427,494 | $21,255 | 797 | - | - |
$64,237 1,427,494 kWh |
$21,255 797 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $155,920 Cost: $1,014,736 |
$349,435 | (-415,994) | - | - | $(-193,515) | (-25,802) |
$349,435 (-415,994) kWh |
- - kW-months/year |
$(-193,515) (-25,802) MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $507,372 Cost: $2,254,093 |
$416,842 | 1,081,935 | $55,191 | 2,069 | $35,339 | 4,667 | $416,842 1,081,935 kWh |
$55,191 2,069 kW-months/year |
$35,339 4,667 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $125,865 Cost: $22,386 |
$2,238 | 49,732 | $33,876 | 1,270 | $89,751 | 11,967 | $2,238 49,732 kWh |
$33,876 1,270 kW-months/year |
$89,751 11,967 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |