Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Illinois, Chicago
Assessment Year 2023
Principal Product Thermoforming Products for Electronics, healthcare, food, and industrial purposes
NAICS 326113 - Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing
SIC 3081 - Unsupported Plastics Film & Sheet
Sales $5,000,000-$10,000,000
# of Employees 56
Plant Area (Sq.Ft.) 27,000
Annual Production 332,179 Pounds
Production Hrs. Annual 4,576
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $27,908 633,840 kWh $0.04
Electricity Demand $22,212 1,364 kW-months/year $16.28
Electricity Fees $17,863 - $ -
Natural Gas $7,821 542 MMBtu $14.42
TOTAL ENERGY COSTS $75,804
RECOMMENDED SAVINGS* $127,731 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $12,982
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$5,197
Cost:
$3,250
$2,638 59,944 $2,560 157 $2,638
59,944
kWh
$2,560
157
kW-months/year
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$6,536
Cost:
$7,857
$3,319 75,430 $3,217 198 $3,319
75,430
kWh
$3,217
198
kW-months/year
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,249
Cost:
$804
$1,066 24,227 $183 11 $1,066
24,227
kWh
$183
11
kW-months/year
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$1,327
Cost:
$2,879
$1,232 28,001 $95 6 $1,232
28,001
kWh
$95
6
kW-months/year
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$109,160
Cost:
$660,787
$33,928 771,092 $75,232 4,620 $33,928
771,092
kWh
$75,232
4,620
kW-months/year
06: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$4,262
Cost:
$5,407
$1,677 38,102 $2,585 159 $1,677
38,102
kWh
$2,585
159
kW-months/year
TOTAL RECOMMENDED Savings:
$127,731
Cost:
$680,984
$43,859 996,796 $83,872 5,150 $43,859
996,796
kWh
$83,872
5,150
kW-months/year
TOTAL IMPLEMENTED Savings:
$12,982
Cost:
$11,911
$7,023 159,601 $5,960 366 $7,023
159,601
kWh
$5,960
366
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand