Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Illinois, Chicago
Assessment Year 2024
Principal Product Biosolids and Sludge
NAICS 221320 - Sewage Treatment Facilities
SIC 4952 - Sewerage Systems
Sales <$500,000
# of Employees 50
Plant Area (Sq.Ft.) 4,000,000
Annual Production 11,630,000 Thousand Gallons
Production Hrs. Annual 8,760
Location (State) IA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,859,642 95,968,800 kWh $0.02
Electricity Demand $1,442,693 72,961 kW-months/year $19.77
Electricity Fees $(-202,949) - $ -
Natural Gas $1,392,367 262,287 MMBtu $5.31
TOTAL ENERGY COSTS $4,491,753
RECOMMENDED SAVINGS* $890,839 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $474,326
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$5,372
Cost:
$2,712
$2,215 116,568 $3,157 160 - - $2,215
116,568
kWh
$3,157
160
kW-months/year
-
-
MMBtu
02: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$23,893
Cost:
$3,458
- - - - $23,893 4,500 -
-
kWh
-
-
kW-months/year
$23,893
4,500
MMBtu
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$554
Cost:
$642
$229 12,042 $325 16 - - $229
12,042
kWh
$325
16
kW-months/year
-
-
MMBtu
04: 2.2427 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS Savings:
$89,084
Cost:
$34,144
- - - - $89,084 16,777 -
-
kWh
-
-
kW-months/year
$89,084
16,777
MMBtu
05: 2.2422 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM Savings:
$263,888
Cost:
$200,000
- - - - $263,888 49,697 -
-
kWh
-
-
kW-months/year
$263,888
49,697
MMBtu
06: 2.1331 BURN A LESS EXPENSIVE GRADE OF FUEL Savings:
$447,899
Cost:
$23,503
- - - - $447,899 84,350 -
-
kWh
-
-
kW-months/year
$447,899
84,350
MMBtu
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$1,379
Cost:
$8,310
$79 4,126 $27 1 $1,273 240 $79
4,126
kWh
$27
1
kW-months/year
$1,273
240
MMBtu
08: 2.2511 INSULATE BARE EQUIPMENT Savings:
$1,981
Cost:
$847
- - - - $1,981 373 -
-
kWh
-
-
kW-months/year
$1,981
373
MMBtu
09: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$56,790
Cost:
$31,894
$23,413 1,232,286 $33,377 1,688 - - $23,413
1,232,286
kWh
$33,377
1,688
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$890,839
Cost:
$305,510
$25,936 1,365,022 $36,885 1,865 $828,018 155,936 $25,936
1,365,022
kWh
$36,885
1,865
kW-months/year
$828,018
155,936
MMBtu
TOTAL IMPLEMENTED Savings:
$474,326
Cost:
$28,450
$229 12,042 $325 16 $473,773 89,223 $229
12,042
kWh
$325
16
kW-months/year
$473,773
89,223
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas