IAC logo
IAC Assessment: IC0306
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: IC0306
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Illinois, Chicago
Assessment Year 2024
Principal Product Electric Heaters
NAICS 333414 - Heating Equipment (except Warm Air Furnaces) Manufacturing
SIC 3822 - Environmental Controls
Sales $50,000,000-$100,000,000
# of Employees 375
Plant Area (Sq.Ft.) 221,000
Annual Production 100,000 Pieces
Production Hrs. Annual 4,420
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $255,099 3,828,976 kWh $0.07
Electricity Demand $140,110 13,149 kW-months/year $10.66
Electricity Fees $34,888 - $ -
Natural Gas $155,234 27,141 MMBtu $5.72
TOTAL ENERGY COSTS $585,331
RECOMMENDED SAVINGS* $368,028 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$274,832
Cost:
$1,429,458
$140,835 2,102,020 $133,996 12,570 - - $140,835
2,102,020
kWh
$133,996
12,570
kW-months/year
-
-
MMBtu
02: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$22,099
Cost:
$10,776
$22,099 329,832 - - - - $22,099
329,832
kWh
-
-
kW-months/year
-
-
MMBtu
03: 2.5122 REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS Savings:
$2,629
Cost:
$118
$1,836 27,404 $793 74 - - $1,836
27,404
kWh
$793
74
kW-months/year
-
-
MMBtu
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$21,638
Cost:
$33,160
$829 12,372 $20,810 1,952 - - $829
12,372
kWh
$20,810
1,952
kW-months/year
-
-
MMBtu
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,340
Cost:
-
$2,085 31,123 $1,255 118 - - $2,085
31,123
kWh
$1,255
118
kW-months/year
-
-
MMBtu
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$158
Cost:
$432
$98 1,459 $60 6 - - $98
1,459
kWh
$60
6
kW-months/year
-
-
MMBtu
07: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$1,874
Cost:
$10,418
$1,089 16,249 - - $785 138 $1,089
16,249
kWh
-
-
kW-months/year
$785
138
MMBtu
08: 2.2511 INSULATE BARE EQUIPMENT Savings:
$41,459
Cost:
$20,803
$6,751 100,762 $2,916 274 $31,791 5,577 $6,751
100,762
kWh
$2,916
274
kW-months/year
$31,791
5,577
MMBtu
TOTAL RECOMMENDED Savings:
$368,028
Cost:
$1,505,165
$175,622 2,621,221 $159,830 14,994 $32,576 5,715 $175,622
2,621,221
kWh
$159,830
14,994
kW-months/year
$32,576
5,715
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas