IAC logo
IAC Assessment: IC0317
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: IC0317
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Illinois, Chicago
Assessment Year 2025
Principal Product Nickel and Chromium Electroplating
NAICS 332813 - Electroplating, Plating, Polishing, Anodizing, and Coloring
SIC 3479 - Metal Coating And Allied Services
Sales $5,000,000-$10,000,000
# of Employees 25
Plant Area (Sq.Ft.) 40,000
Annual Production 100,000 Units
Production Hrs. Annual 4,420
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $90,130 2,346,232 kWh $0.04
Electricity Demand $68,483 6,362 kW-months/year $10.76
Electricity Fees $106,406 - $ -
Natural Gas $260,786 33,473 MMBtu $7.79
TOTAL ENERGY COSTS $542,831
RECOMMENDED SAVINGS* $83,459 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.3312 INSTALL EFFICIENT RECTIFIERS Savings:
$6,191
Cost:
$19,124
$3,499 92,083 $2,692 250 - - $3,499
92,083
kWh
$2,692
250
kW-months/year
-
-
MMBtu
02: 2.7316 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN Savings:
$10,127
Cost:
$7,240
$10,127 266,507 - - - - $10,127
266,507
kWh
-
-
kW-months/year
-
-
MMBtu
03: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$930
Cost:
-
- - $930 86 - - -
-
kWh
$930
86
kW-months/year
-
-
MMBtu
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$431
Cost:
$1,113
$244 6,409 $187 17 - - $244
6,409
kWh
$187
17
kW-months/year
-
-
MMBtu
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$2,337
Cost:
$108
$305 8,038 $2,032 189 - - $305
8,038
kWh
$2,032
189
kW-months/year
-
-
MMBtu
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$704
Cost:
-
$398 10,467 $306 28 - - $398
10,467
kWh
$306
28
kW-months/year
-
-
MMBtu
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$32,668
Cost:
$258,530
$10,685 281,194 $21,982 2,042 - - $10,685
281,194
kWh
$21,982
2,042
kW-months/year
-
-
MMBtu
08: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$15,053
Cost:
$20,087
$(-2,687) (-70,704) $(-6,201) (-576) $23,941 3,073 $(-2,687)
(-70,704)
kWh
$(-6,201)
(-576)
kW-months/year
$23,941
3,073
MMBtu
09: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$972
Cost:
$2,234
$551 14,496 $421 39 - - $551
14,496
kWh
$421
39
kW-months/year
-
-
MMBtu
10: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$397
Cost:
$597
$208 5,468 $189 18 - - $208
5,468
kWh
$189
18
kW-months/year
-
-
MMBtu
11: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$151
Cost:
$425
$46 1,222 $104 10 - - $46
1,222
kWh
$104
10
kW-months/year
-
-
MMBtu
12: 2.1223 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) Savings:
$11,344
Cost:
$21,200
- - - - $11,344 1,456 -
-
kWh
-
-
kW-months/year
$11,344
1,456
MMBtu
13: 2.2511 INSULATE BARE EQUIPMENT Savings:
$2,154
Cost:
$4,516
$806 21,216 $620 58 $728 93 $806
21,216
kWh
$620
58
kW-months/year
$728
93
MMBtu
TOTAL RECOMMENDED Savings:
$83,459
Cost:
$335,174
$24,183 636,397 $23,263 2,161 $36,013 4,623 $24,183
636,397
kWh
$23,263
2,161
kW-months/year
$36,013
4,623
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas