Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Indiana University-Purdue University |
---|---|
Assessment Year | 2016 |
Principal Product | Residential Furnace & fan coils |
NAICS | 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
SIC | 3585 - Refrigeration And Heating Equipment |
Sales | >$500,000,000 |
# of Employees | 500 |
Plant Area (Sq.Ft.) | 600,000 |
Annual Production | 1,600,000 Pieces |
Production Hrs. Annual | 5,052 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,073,115 | 21,498,400 | kWh | $0.05 |
Electricity Demand | $501,315 | 44,684 | kW-months/year | $11.22 |
Electricity Fees | $4,433 | - | $ | - |
Natural Gas | $414,338 | 82,985 | MMBtu | $4.99 |
TOTAL ENERGY COSTS | $2,031,605 | |||
RECOMMENDED SAVINGS* | $98,481 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $10,007 Cost: $326 |
$10,007 | 200,452 | - | - | - | - | - | - | - | - | - | - |
$10,007 200,452 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $256 Cost: $51 |
$256 | 5,138 | - | - | - | - | - | - | - | - | - | - |
$256 5,138 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3192 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS |
Savings: $30,281 Cost: $6,819 |
$624 | 12,500 | $31,820 | 2,836 | - | - | - | - | - | - | $(-2,163) | - |
$624 12,500 kWh |
$31,820 2,836 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
$(-2,163) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2426 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR |
Savings: $11,137 Cost: $4,626 |
- | - | - | - | - | - | $11,137 | 2,231 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$11,137 2,231 MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4145 USE MAGNETIC TECHNOLOGY TO TREAT WATER |
Savings: $227 Cost: $255 |
- | - | - | - | - | - | - | - | $227 | 62 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$227 62 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $46,574 Cost: $102,745 |
- | - | - | - | $46,574 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$46,574 - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $98,481 Cost: $114,822 |
$10,887 | 218,090 | $31,820 | 2,836 | $46,574 | - | $11,137 | 2,231 | $227 | 62 | $(-2,163) | - | $10,887 218,090 kWh |
$31,820 2,836 kW-months/year |
$46,574 - $ |
$11,137 2,231 MMBtu |
$227 62 Tgal |
$(-2,163) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Ancillary Material Cost |