Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Indiana University-Purdue University |
---|---|
Assessment Year | 2017 |
Principal Product | Aluminum Castings |
NAICS | 331524 - Aluminum Foundries (except Die-Casting) |
SIC | 3365 - Aluminum Foundries |
Sales | $10,000,000-$50,000,000 |
# of Employees | 140 |
Plant Area (Sq.Ft.) | 168,000 |
Annual Production | 189,099 Pieces |
Production Hrs. Annual | 4,500 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $481,737 | 7,255,800 | kWh | $0.07 |
Electricity Demand | $229,514 | 20,252 | kW-months/year | $11.33 |
Electricity Fees | $82,781 | - | $ | - |
Natural Gas | $341,010 | 102,958 | MMBtu | $3.31 |
TOTAL ENERGY COSTS | $1,135,042 | |||
RECOMMENDED SAVINGS* | $193,216 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $97,740 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $5,047 Cost: $6 |
$3,471 | 52,267 | $1,576 | 139 | - | - | - | - |
$3,471 52,267 kWh |
$1,576 139 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $3,466 Cost: - |
$2,809 | 42,311 | $657 | 58 | - | - | - | - |
$2,809 42,311 kWh |
$657 58 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $35,073 Cost: $678 |
$11,174 | 168,286 | - | - | - | - | $23,899 | 7,220 |
$11,174 168,286 kWh |
- - kW-months/year |
- - $ |
$23,899 7,220 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,340 Cost: $147 |
$4,357 | 65,612 | $1,983 | 175 | - | - | - | - |
$4,357 65,612 kWh |
$1,983 175 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2514 COVER OPEN TANKS |
Savings: $20,504 Cost: $766 |
- | - | - | - | - | - | $20,504 | 6,195 |
- - kWh |
- - kW-months/year |
- - $ |
$20,504 6,195 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,135 Cost: $302 |
$3,135 | 47,210 | - | - | - | - | - | - |
$3,135 47,210 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $12,652 Cost: $1,239 |
$12,652 | 190,540 | - | - | - | - | - | - |
$12,652 190,540 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4238 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING |
Savings: $742 Cost: $90 |
$742 | 11,170 | - | - | - | - | - | - |
$742 11,170 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.812 APPLY FOR INVESTMENT INCENTIVES |
Savings: $38,196 Cost: $5,000 |
- | - | - | - | $38,196 | - | - | - |
- - kWh |
- - kW-months/year |
$38,196 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $12,415 Cost: $9,367 |
$12,415 | 186,975 | - | - | - | - | - | - |
$12,415 186,975 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,761 Cost: $2,448 |
$1,210 | 18,225 | $551 | 49 | - | - | - | - |
$1,210 18,225 kWh |
$551 49 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $23,934 Cost: $35,575 |
- | - | - | - | $23,934 | - | - | - |
- - kWh |
- - kW-months/year |
$23,934 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 4.812 APPLY FOR INVESTMENT INCENTIVES |
Savings: $2,977 Cost: $5,000 |
- | - | - | - | $2,977 | - | - | - |
- - kWh |
- - kW-months/year |
$2,977 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $10,861 Cost: $3,300 |
- | - | - | - | - | - | $10,861 | 3,281 |
- - kWh |
- - kW-months/year |
- - $ |
$10,861 3,281 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $16,112 Cost: $79,976 |
$11,074 | 166,770 | $5,038 | 445 | - | - | - | - |
$11,074 166,770 kWh |
$5,038 445 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $193,216 Cost: $143,894 |
$63,039 | 949,366 | $9,805 | 866 | $65,107 | - | $55,264 | 16,696 | $63,039 949,366 kWh |
$9,805 866 kW-months/year |
$65,107 - $ |
$55,264 16,696 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $97,740 Cost: $46,584 |
$8,570 | 129,049 | $3,559 | 314 | $65,107 | - | $20,504 | 6,195 | $8,570 129,049 kWh |
$3,559 314 kW-months/year |
$65,107 - $ |
$20,504 6,195 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |