Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Indiana University-Purdue University |
---|---|
Assessment Year | 2017 |
Principal Product | Refined Soybean Oil and Meal |
NAICS | 311225 - Fats and Oils Refining and Blending |
SIC | 2075 - Soybean Oil Mills |
Sales | >$500,000,000 |
# of Employees | 113 |
Plant Area (Sq.Ft.) | 5,096,520 |
Annual Production | 700,000,000 Pounds |
Production Hrs. Annual | 8,400 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $3,031,000 | 62,225,622 | kWh | $0.05 |
Electricity Demand | $1,154,068 | 100,704 | kW-months/year | $11.46 |
Electricity Fees | $46,249 | - | $ | - |
Natural Gas | $3,423,261 | 1,173,415 | MMBtu | $2.92 |
TOTAL ENERGY COSTS | $7,993,500 | |||
RECOMMENDED SAVINGS* | $677,041 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $63,752 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $1,035 Cost: - |
$783 | 16,031 | $252 | 22 | - | - | - | - |
$783 16,031 kWh |
$252 22 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $23,755 Cost: $72 |
$11,850 | 242,822 | - | - | $11,905 | 4,077 | - | - |
$11,850 242,822 kWh |
- - kW-months/year |
$11,905 4,077 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,755 Cost: $189 |
$1,314 | 26,929 | $441 | 38 | - | - | - | - |
$1,314 26,929 kWh |
$441 38 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,851 Cost: $308 |
$3,851 | 78,909 | - | - | - | - | - | - |
$3,851 78,909 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $5,139 Cost: $432 |
- | - | - | - | $5,139 | 1,760 | - | - |
- - kWh |
- - kW-months/year |
$5,139 1,760 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $21,213 Cost: $2,430 |
$15,884 | 325,500 | $5,329 | 465 | - | - | - | - |
$15,884 325,500 kWh |
$5,329 465 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $13,313 Cost: $7,280 |
$9,969 | 204,288 | $3,344 | 292 | - | - | - | - |
$9,969 204,288 kWh |
$3,344 292 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $509 Cost: $529 |
$509 | 10,430 | - | - | - | - | - | - |
$509 10,430 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $332 Cost: $798 |
$251 | 5,151 | $81 | 7 | - | - | - | - |
$251 5,151 kWh |
$81 7 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $606,139 Cost: $2,150,000 |
$798,550 | 16,363,740 | $267,456 | 23,338 | $86,829 | 29,736 | $(-546,696) | - |
$798,550 16,363,740 kWh |
$267,456 23,338 kW-months/year |
$86,829 29,736 MMBtu |
$(-546,696) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $677,041 Cost: $2,162,038 |
$842,961 | 17,273,800 | $276,903 | 24,162 | $103,873 | 35,573 | $(-546,696) | - | $842,961 17,273,800 kWh |
$276,903 24,162 kW-months/year |
$103,873 35,573 MMBtu |
$(-546,696) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $63,752 Cost: $11,012 |
$37,954 | 777,761 | $8,754 | 764 | $17,044 | 5,837 | - | - | $37,954 777,761 kWh |
$8,754 764 kW-months/year |
$17,044 5,837 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||