IAC Center Indiana University-Purdue University
Assessment Year 2018
Principal Product fiberglass backing
NAICS 326199 - All Other Plastics Product Manufacturing
SIC 3089 - Plastics Products, Nec
Sales $95,900,000
# of Employees 93
Plant Area (Sq.Ft.) 468,000
Annual Production 97,734,287 not found
Production Hrs. Annual 8,616
Location (State) IL
Source Yearly Cost Usage
Electricity Usage $1,300,701 28,800,595
Electricity Demand $90,049 44,585
Electricity Fees $117,692 -
Natural Gas $1,973,929 598,559
TOTAL ENERGY COSTS $3,482,371
RECOMMENDED SAVINGS* $12,974 *Non-energy impacts
included in savings.
IMPLEMENTED SAVINGS* $5,707
#|Description Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW/month $ MMBtu
01: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$4,724
Cost:
-
$2,414 53,644 - - $2,310 700 $2,414
53,644
kWh
-
-
kW/month
$2,310
700
MMBtu
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$548
Cost:
$1,325
$548 12,187 - - - - $548
12,187
kWh
-
-
kW/month
-
-
MMBtu
03: 2.2434 RECOVER HEAT FROM AIR COMPRESSOR Savings:
$2,543
Cost:
$9,687
$(-550) (-12,212) $(-38) (-19) $3,130 949 $(-550)
(-12,212)
kWh
$(-38)
(-19)
kW/month
$3,130
949
MMBtu
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,159
Cost:
$21,897
$4,595 102,119 $564 279 - - $4,595
102,119
kWh
$564
279
kW/month
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$12,974
Cost:
$32,909
$7,008 155,738 $526 260 $5,440 1,649 $7,008
155,738
kWh
$526
260
kW/month
$5,440
1,649
MMBtu
TOTAL IMPLEMENTED Savings:
$5,707
Cost:
$23,222
$5,143 114,306 $564 279 - - $5,143
114,306
kWh
$564
279
kW/month
-
-
MMBtu
$ kWh $ kW/month $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
Back to Top