IAC logo
IAC Assessment: IP0161
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: IP0161
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Indiana University-Purdue University
Assessment Year 2022
Principal Product Food Bank
NAICS 311999 - All Other Miscellaneous Food Manufacturing
SIC 2099 - Food Preparations, Nec
Sales $100,000,000-$500,000,000
# of Employees 95
Plant Area (Sq.Ft.) 300,000
Annual Production 100,000,000 Pounds
Production Hrs. Annual 2,496
Location (State) IN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $117,537 2,614,000 kWh $0.04
Electricity Demand $128,820 6,014 kW-months/year $21.42
Natural Gas $10,728 6,203 MMBtu $1.73
TOTAL ENERGY COSTS $257,085
RECOMMENDED SAVINGS* $9,358 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,209
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$94
Cost:
-
$57 1,261 $37 2 - - $57
1,261
kWh
$37
2
kW-months/year
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,573
Cost:
-
$1,179 26,208 $394 18 - - $1,179
26,208
kWh
$394
18
kW-months/year
-
-
MMBtu
03: 2.7212 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS Savings:
$1,152
Cost:
$88
$698 15,498 $454 21 - - $698
15,498
kWh
$454
21
kW-months/year
-
-
MMBtu
04: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$709
Cost:
$1,601
- - - - $709 410 -
-
kWh
-
-
kW-months/year
$709
410
MMBtu
05: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$5,440
Cost:
$13,298
$5,440 120,888 - - - - $5,440
120,888
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$128
Cost:
$328
$128 2,847 - - - - $128
2,847
kWh
-
-
kW-months/year
-
-
MMBtu
07: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$262
Cost:
$724
$262 5,820 - - - - $262
5,820
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$9,358
Cost:
$16,039
$7,764 172,522 $885 41 $709 410 $7,764
172,522
kWh
$885
41
kW-months/year
$709
410
MMBtu
TOTAL IMPLEMENTED Savings:
$3,209
Cost:
$1,140
$2,324 51,634 $885 41 - - $2,324
51,634
kWh
$885
41
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas