Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Indiana University-Purdue University |
---|---|
Assessment Year | 2022 |
Principal Product | Automotive Fuel & Air Management Systems |
NAICS | 336390 - Other Motor Vehicle Parts Manufacturing |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $100,000,000-$500,000,000 |
# of Employees | 391 |
Plant Area (Sq.Ft.) | 412,803 |
Annual Production | 6,100,000 Units |
Production Hrs. Annual | 7,200 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,367,324 | 32,883,200 | kWh | $0.04 |
Electricity Demand | $1,500,242 | 127,471 | kW-months/year | $11.77 |
Electricity Fees | $14,335 | - | $ | - |
Natural Gas | $547,549 | 211,698 | MMBtu | $2.59 |
TOTAL ENERGY COSTS | $3,498,088 | |||
RECOMMENDED SAVINGS* | $89,330 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $56,613 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $17,520 Cost: $2,500 |
- | - | - | - | - | - | $17,520 | 3,504 |
- - kWh |
- - kW-months/year |
- - $ |
$17,520 3,504 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $33,801 Cost: $3,457 |
$32,535 | 774,648 | $1,266 | 108 | - | - | - | - |
$32,535 774,648 kWh |
$1,266 108 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,573 Cost: $475 |
$1,754 | 41,760 | $819 | 70 | - | - | - | - |
$1,754 41,760 kWh |
$819 70 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7229 AIR CONDITION ONLY SPACE NECESSARY |
Savings: $6,333 Cost: $2,520 |
$253 | 6,013 | - | - | - | - | $6,080 | 1,216 |
$253 6,013 kWh |
- - kW-months/year |
- - $ |
$6,080 1,216 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,306 Cost: $3,300 |
$3,306 | 78,714 | - | - | - | - | - | - |
$3,306 78,714 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,236 Cost: $2,330 |
$1,236 | 30,571 | - | - | - | - | - | - |
$1,236 30,571 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $369 Cost: $730 |
$369 | 8,786 | - | - | - | - | - | - |
$369 8,786 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $10,286 Cost: $21,879 |
- | - | - | - | - | - | $10,286 | 15,038 |
- - kWh |
- - kW-months/year |
- - $ |
$10,286 15,038 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $11,341 Cost: $26,639 |
- | - | - | - | $11,341 | - | - | - |
- - kWh |
- - kW-months/year |
$11,341 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,565 Cost: $8,140 |
$2,565 | 61,071 | - | - | - | - | - | - |
$2,565 61,071 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $89,330 Cost: $71,970 |
$42,018 | 1,001,563 | $2,085 | 177 | $11,341 | - | $33,886 | 19,758 | $42,018 1,001,563 kWh |
$2,085 177 kW-months/year |
$11,341 - $ |
$33,886 19,758 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $56,613 Cost: $41,231 |
$37,107 | 883,492 | $2,085 | 177 | $11,341 | - | $6,080 | 1,216 | $37,107 883,492 kWh |
$2,085 177 kW-months/year |
$11,341 - $ |
$6,080 1,216 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |