Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, Kingsville |
---|---|
Assessment Year | 1996 |
Principal Product | poultry feed |
NAICS | n/a |
SIC | 2048 - Prepared Feeds, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 15 |
Plant Area (Sq.Ft.) | 14,150 |
Annual Production | 170,000 Tons |
Production Hrs. Annual | 6,240 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $124,007 | 3,546,893 | kWh | $0.03 |
Electricity Demand | $49,201 | 8,758 | kW-months/year | $5.62 |
Electricity Fees | $1,800 | - | $ | - |
Natural Gas | $107,208 | 23,898 | MMBtu | $4.49 |
TOTAL ENERGY COSTS | $282,216 | |||
RECOMMENDED SAVINGS* | $20,367 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $16,877 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $10,326 Cost: $21,750 |
$9,156 | 261,723 | $1,170 | 348 | - | - | - | - |
$9,156 261,723 kWh |
$1,170 348 kW-months/year |
- - Tgal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $2,934 Cost: - |
$2,470 | 70,633 | $464 | 132 | - | - | - | - |
$2,470 70,633 kWh |
$464 132 kW-months/year |
- - Tgal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $900 Cost: $20 |
$778 | 22,274 | $122 | 36 | - | - | - | - |
$778 22,274 kWh |
$122 36 kW-months/year |
- - Tgal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE |
Savings: $712 Cost: $1,890 |
$712 | 16,706 | - | - | - | - | - | - |
$712 16,706 kWh |
- - kW-months/year |
- - Tgal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $2,282 Cost: $275 |
- | - | - | - | - | - | $2,282 | 15,600 |
- - kWh |
- - kW-months/year |
- - Tgal |
$2,282 15,600 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4154 ELIMINATE LEAKS IN WATER LINES AND VALVES |
Savings: $2,657 Cost: - |
- | - | - | - | $2,657 | 539,225 | - | - |
- - kWh |
- - kW-months/year |
$2,657 539,225 Tgal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $556 Cost: - |
- | - | - | - | - | - | $556 | 3,600 |
- - kWh |
- - kW-months/year |
- - Tgal |
$556 3,600 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $20,367 Cost: $23,935 |
$13,116 | 371,336 | $1,756 | 516 | $2,657 | 539,225 | $2,838 | 19,200 | $13,116 371,336 kWh |
$1,756 516 kW-months/year |
$2,657 539,225 Tgal |
$2,838 19,200 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $16,877 Cost: $23,935 |
$10,646 | 300,703 | $1,292 | 384 | $2,657 | 539,225 | $2,282 | 15,600 | $10,646 300,703 kWh |
$1,292 384 kW-months/year |
$2,657 539,225 Tgal |
$2,282 15,600 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) |