Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, Kingsville |
---|---|
Assessment Year | 1997 |
Principal Product | Printed pamphlets and fliers. |
NAICS | n/a |
SIC | 2741 - Miscellaneous Publishing |
Sales | $5,000,000-$10,000,000 |
# of Employees | 78 |
Plant Area (Sq.Ft.) | 42,000 |
Annual Production | 30,600,000 Pieces |
Production Hrs. Annual | 7,344 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $40,084 | 1,138,628 | kWh | $0.04 |
Electricity Demand | $21,195 | 3,569 | kW-months/year | $5.94 |
Electricity Fees | $1,662 | - | $ | - |
Natural Gas | $305 | 53 | MMBtu | $5.75 |
TOTAL ENERGY COSTS | $105,233 | |||
RECOMMENDED SAVINGS* | $84,254 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Product | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $2,976 Cost: $1,650 |
$2,976 | 86,753 | - | - | - | - | - | - |
$2,976 86,753 kWh |
- - kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,348 Cost: $660 |
$1,742 | 48,359 | $606 | 100 | - | - | - | - |
$1,742 48,359 kWh |
$606 100 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7292 LOWER CEILING TO REDUCE CONDITIONED SPACE |
Savings: $1,251 Cost: $1,200 |
$1,251 | 34,877 | - | - | - | - | - | - |
$1,251 34,877 kWh |
- - kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $7,246 Cost: - |
- | - | - | - | $7,246 | - | - | - |
- - kWh |
- - kW-months/year |
$7,246 - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $1,239 Cost: - |
- | - | - | - | $1,239 | 8,862 | - | - |
- - kWh |
- - kW-months/year |
$1,239 8,862 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.131 MODIFY PROCESS TO REDUCE MATERIAL USE/COST |
Savings: $38,595 Cost: $5,350 |
- | - | - | - | - | - | $38,595 | - |
- - kWh |
- - kW-months/year |
- - lb |
$38,595 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.131 MODIFY PROCESS TO REDUCE MATERIAL USE/COST |
Savings: $30,599 Cost: $4,600 |
- | - | - | - | - | - | $30,599 | - |
- - kWh |
- - kW-months/year |
- - lb |
$30,599 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $84,254 Cost: $13,460 |
$5,969 | 169,989 | $606 | 100 | $8,485 | 8,862 | $69,194 | - | $5,969 169,989 kWh |
$606 100 kW-months/year |
$8,485 8,862 lb |
$69,194 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Product | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Product |