Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Kennesaw State |
---|---|
Assessment Year | 2023 |
Principal Product | Resilient Flooring |
NAICS | 326199 - All Other Plastics Product Manufacturing |
SIC | 3996 - Hard Surface Floor Coverings, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 167 |
Plant Area (Sq.Ft.) | 129,000 |
Annual Production | 65,000,000 Units |
Production Hrs. Annual | 6,240 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,212,491 | 15,661,652 | kWh | $0.08 |
Natural Gas | $675,170 | 55,159 | MMBtu | $12.24 |
TOTAL ENERGY COSTS | $1,904,222 | |||
RECOMMENDED SAVINGS* | $175,330 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $12,574 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Personnel Changes | Administrative Changes | Electricity Usage | Natural Gas | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $12,574 Cost: $6,440 |
$12,574 | 141,286 | - | - | - | - | - | - |
$12,574 141,286 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC |
Savings: $19,596 Cost: $10,708 |
- | - | $19,596 | 1,601 | - | - | - | - |
- - kWh |
$19,596 1,601 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2123 INSULATE FEEDWATER TANK |
Savings: $4,841 Cost: $4,104 |
- | - | $4,841 | 396 | - | - | - | - |
- - kWh |
$4,841 396 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $13,819 Cost: $3,753 |
- | - | $13,819 | 1,129 | - | - | - | - |
- - kWh |
$13,819 1,129 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $1,129 Cost: - |
- | - | $1,909 | 156 | - | - | $(-780) | - |
- - kWh |
$1,909 156 MMBtu |
- - $ |
$(-780) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT |
Savings: $66,324 Cost: $627,000 |
$111,072 | 1,248,000 | $(-38,348) | (-3,133) | $(-6,400) | - | - | - |
$111,072 1,248,000 kWh |
$(-38,348) (-3,133) MMBtu |
$(-6,400) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $57,047 Cost: $422,421 |
$57,047 | 640,983 | - | - | - | - | - | - |
$57,047 640,983 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $175,330 Cost: $1,074,426 |
$180,693 | 2,030,269 | $1,817 | 149 | $(-6,400) | - | $(-780) | - | $180,693 2,030,269 kWh |
$1,817 149 MMBtu |
$(-6,400) - $ |
$(-780) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $12,574 Cost: $6,440 |
$12,574 | 141,286 | - | - | - | - | - | - | $12,574 141,286 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Personnel Changes | Administrative Changes | Electricity Usage | Natural Gas | Personnel Changes | Administrative Changes |