IAC logo
IAC Assessment: KS2319
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: KS2319
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Kennesaw State
Assessment Year 2023
Principal Product Fabricated Metal Products
NAICS 332999 - All Other Miscellaneous Fabricated Metal Product Manufacturing
SIC 3499 - Fabricated Metal Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 180
Plant Area (Sq.Ft.) 160,000
Annual Production 1,200,000 Units
Production Hrs. Annual 7,140
Location (State) SC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $127,137 2,686,516 kWh $0.05
Electricity Demand $111,656 7,978 kW-months/year $14.00
Natural Gas $7,969 811 MMBtu $9.82
TOTAL ENERGY COSTS $258,352
RECOMMENDED SAVINGS* $137,268 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$6,385
Cost:
$5,960
$4,264 90,155 $2,121 152 - - - - $4,264
90,155
kWh
$2,121
152
kW-months/year
-
-
MMBtu
-
-
$
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$593
Cost:
$60
$396 8,369 $197 14 - - - - $396
8,369
kWh
$197
14
kW-months/year
-
-
MMBtu
-
-
$
03: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER Savings:
$2,009
Cost:
$5,440
- - - - $2,009 205 - - -
-
kWh
-
-
kW-months/year
$2,009
205
MMBtu
-
-
$
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$307
Cost:
$119
$112 2,366 $195 14 - - - - $112
2,366
kWh
$195
14
kW-months/year
-
-
MMBtu
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,663
Cost:
$19,796
$1,891 39,984 $941 67 - - $1,831 - $1,891
39,984
kWh
$941
67
kW-months/year
-
-
MMBtu
$1,831
-
$
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$123,311
Cost:
$1,196,880
$109,507 1,871,456 $13,804 986 - - - - $109,507
1,871,456
kWh
$13,804
986
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$137,268
Cost:
$1,228,255
$116,170 2,012,330 $17,258 1,233 $2,009 205 $1,831 - $116,170
2,012,330
kWh
$17,258
1,233
kW-months/year
$2,009
205
MMBtu
$1,831
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes