Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Kennesaw State |
---|---|
Assessment Year | 2023 |
Principal Product | Chemical Manufacturing |
NAICS | 325180 - Other Basic Inorganic Chemical Manufacturing |
SIC | 2819 - Industrial Inorganic Chemicals, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 38 |
Plant Area (Sq.Ft.) | 74,000 |
Annual Production | 660,000 Pounds |
Production Hrs. Annual | 8,400 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $80,048 | 2,097,375 | kWh | $0.04 |
Natural Gas | $300,904 | 34,901 | MMBtu | $8.62 |
TOTAL ENERGY COSTS | $448,003 | |||
RECOMMENDED SAVINGS* | $261,738 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Water Usage | Water Disposal | Administrative Changes | Electricity Usage | Natural Gas | Water Usage | Water Disposal | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $89,035 Cost: $701,322 |
$89,035 | 890,353 | - | - | - | - | - | - | - | - |
$89,035 890,353 kWh |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,032 Cost: $5,480 |
$4,032 | 40,320 | - | - | - | - | - | - | - | - |
$4,032 40,320 kWh |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $646 Cost: $1,328 |
$646 | 6,462 | - | - | - | - | - | - | - | - |
$646 6,462 kWh |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,362 Cost: $3,175 |
$1,075 | 10,752 | - | - | - | - | - | - | $287 | - |
$1,075 10,752 kWh |
- - MMBtu |
- - Tgal |
- - Tgal |
$287 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,194 Cost: $18,538 |
$3,410 | 34,104 | - | - | - | - | - | - | $2,784 | - |
$3,410 34,104 kWh |
- - MMBtu |
- - Tgal |
- - Tgal |
$2,784 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT |
Savings: $125,249 Cost: $627,000 |
$168,000 | 1,680,000 | $(-36,351) | (-4,217) | - | - | - | - | $(-6,400) | - |
$168,000 1,680,000 kWh |
$(-36,351) (-4,217) MMBtu |
- - Tgal |
- - Tgal |
$(-6,400) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $5,241 Cost: $1,770 |
- | - | $5,241 | 608 | - | - | - | - | - | - |
- - kWh |
$5,241 608 MMBtu |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4154 ELIMINATE LEAKS IN WATER LINES AND VALVES |
Savings: $29,979 Cost: $30 |
- | - | $12,197 | 1,415 | $7,686 | 968 | $10,096 | 968 | - | - |
- - kWh |
$12,197 1,415 MMBtu |
$7,686 968 Tgal |
$10,096 968 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $261,738 Cost: $1,358,643 |
$266,198 | 2,661,991 | $(-18,913) | (-2,194) | $7,686 | 968 | $10,096 | 968 | $(-3,329) | - | $266,198 2,661,991 kWh |
$(-18,913) (-2,194) MMBtu |
$7,686 968 Tgal |
$10,096 968 Tgal |
$(-3,329) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Water Usage | Water Disposal | Administrative Changes | Electricity Usage | Natural Gas | Water Usage | Water Disposal | Administrative Changes |