IAC logo
IAC Assessment: KU0061
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: KU0061
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Univ. of Kansas
Assessment Year 1982
Principal Product FULLY-COOKED LUNCH MEATS
NAICS n/a
SIC 2013 - Sausages And Other Prepared Meats
Sales $10,000,000-$50,000,000
# of Employees 140
Plant Area (Sq.Ft.) 0
Annual Production 20,000,000 Pounds
Production Hrs. Annual 4,437
Location (State) KS
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $140,644 3,711,899 kWh $0.04
Natural Gas $61,527 20,686 MMBtu $2.97
TOTAL ENERGY COSTS $202,171
RECOMMENDED SAVINGS* $22,819 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,078
Cost:
$3,361
$4,078 107,562 - - $4,078
107,562
kWh
-
-
MMBtu
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$2,765
Cost:
$1,000
- - $2,765 931 -
-
kWh
$2,765
931
MMBtu
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$1,549
Cost:
$1,200
$1,032 27,257 $517 174 $1,032
27,257
kWh
$517
174
MMBtu
04: 2.4324 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT Savings:
$4,660
Cost:
$3,800
$4,660 123,095 - - $4,660
123,095
kWh
-
-
MMBtu
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$9,767
Cost:
$9,000
- - $9,767 3,289 -
-
kWh
$9,767
3,289
MMBtu
TOTAL RECOMMENDED Savings:
$22,819
Cost:
$18,361
$9,770 257,914 $13,049 4,394 $9,770
257,914
kWh
$13,049
4,394
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas