Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Univ. of Kansas
Assessment Year 1986
Principal Product TRUCK BODIES & TRAILERS
NAICS n/a
SIC 3713 - Truck And Bus Bodies
Sales $10,000,000-$50,000,000
# of Employees 70
Plant Area (Sq.Ft.) 0
Annual Production 650 Pieces
Production Hrs. Annual 0
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $64,095 739,156 kWh $0.09
Natural Gas $24,587 5,508 MMBtu $4.46
TOTAL ENERGY COSTS $88,682
RECOMMENDED SAVINGS* $17,560 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $13,044
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$8,919
Cost:
$6,173
$8,919 102,872 - - - - $8,919
102,872
kWh
-
-
MMBtu
-
-
$
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$4,324
Cost:
$6,000
$5,539 63,892 $(-1,215) (-273) - - $5,539
63,892
kWh
$(-1,215)
(-273)
MMBtu
-
-
$
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$1,330
Cost:
$100
$1,330 15,240 - - - - $1,330
15,240
kWh
-
-
MMBtu
-
-
$
04: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$1,289
Cost:
$100
- - $1,289 289 - - -
-
kWh
$1,289
289
MMBtu
-
-
$
05: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$906
Cost:
$34
$152 1,758 $754 169 - - $152
1,758
kWh
$754
169
MMBtu
-
-
$
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$600
Cost:
$200
$600 7,034 - - - - $600
7,034
kWh
-
-
MMBtu
-
-
$
07: 2.1232 KEEP BOILER TUBES CLEAN Savings:
$112
Cost:
$100
- - $162 36 $(-50) - -
-
kWh
$162
36
MMBtu
$(-50)
-
$
08: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$80
Cost:
-
- - $130 29 $(-50) - -
-
kWh
$130
29
MMBtu
$(-50)
-
$
TOTAL RECOMMENDED Savings:
$17,560
Cost:
$12,707
$16,540 190,796 $1,120 250 $(-100) - $16,540
190,796
kWh
$1,120
250
MMBtu
$(-100)
-
$
TOTAL IMPLEMENTED Savings:
$13,044
Cost:
$6,607
$11,001 126,904 $2,043 458 - - $11,001
126,904
kWh
$2,043
458
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes