Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Univ. of Kansas
Assessment Year 1987
Principal Product CORRUGATED CONTAINERS
NAICS n/a
SIC 2653 - Corrugated And Solid Fiber Boxes
Sales $10,000,000-$50,000,000
# of Employees 100
Plant Area (Sq.Ft.) 0
Annual Production 35,000 Tons
Production Hrs. Annual 6,048
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $153,878 2,559,496 kWh $0.06
Natural Gas $181,406 38,130 MMBtu $4.76
TOTAL ENERGY COSTS $335,284
RECOMMENDED SAVINGS* $31,547 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $17,989
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,784
Cost:
$3,862
$3,784 63,013 - - - - $3,784
63,013
kWh
-
-
MMBtu
-
-
$
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$4,993
Cost:
$8,000
- - $4,993 1,049 - - -
-
kWh
$4,993
1,049
MMBtu
-
-
$
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$5,345
Cost:
$4,000
- - $5,345 1,123 - - -
-
kWh
$5,345
1,123
MMBtu
-
-
$
04: 2.1222 INSTALL TURBULATORS Savings:
$4,336
Cost:
$6,311
- - $4,336 911 - - -
-
kWh
$4,336
911
MMBtu
-
-
$
05: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$4,229
Cost:
-
$4,229 70,340 - - - - $4,229
70,340
kWh
-
-
MMBtu
-
-
$
06: 2.2511 INSULATE BARE EQUIPMENT Savings:
$3,013
Cost:
$5,000
- - $3,013 633 - - -
-
kWh
$3,013
633
MMBtu
-
-
$
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,044
Cost:
-
$2,044 33,998 - - - - $2,044
33,998
kWh
-
-
MMBtu
-
-
$
08: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$1,504
Cost:
$140
- - $1,504 316 - - -
-
kWh
$1,504
316
MMBtu
-
-
$
09: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$1,385
Cost:
-
- - $1,585 333 $(-200) - -
-
kWh
$1,585
333
MMBtu
$(-200)
-
$
10: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$544
Cost:
$400
$758 12,603 $(-214) (-45) - - $758
12,603
kWh
$(-214)
(-45)
MMBtu
-
-
$
11: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$370
Cost:
-
$370 6,155 - - - - $370
6,155
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$31,547
Cost:
$27,713
$11,185 186,109 $20,562 4,320 $(-200) - $11,185
186,109
kWh
$20,562
4,320
MMBtu
$(-200)
-
$
TOTAL IMPLEMENTED Savings:
$17,989
Cost:
$13,402
$6,956 115,769 $11,233 2,360 $(-200) - $6,956
115,769
kWh
$11,233
2,360
MMBtu
$(-200)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes