Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Univ. of Kansas
Assessment Year 1989
Principal Product AUTO RADIATORS & COOLERS
NAICS n/a
SIC 3714 - Motor Vehicle Parts And Accessories
Sales $10,000,000-$50,000,000
# of Employees 170
Plant Area (Sq.Ft.) 0
Annual Production 27,500 Pieces
Production Hrs. Annual 3,840
Location (State) IA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $106,791 2,727,140 kWh $0.04
Natural Gas $121,333 28,144 MMBtu $4.31
TOTAL ENERGY COSTS $228,124
RECOMMENDED SAVINGS* $43,595 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $2,753
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$227
Cost:
$118
$227 5,862 - - $227
5,862
kWh
-
-
MMBtu
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$528
Cost:
$130
$528 13,482 - - $528
13,482
kWh
-
-
MMBtu
03: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$360
Cost:
$41
$149 3,810 $211 49 $149
3,810
kWh
$211
49
MMBtu
04: 2.6121 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED Savings:
$345
Cost:
-
- - $345 80 -
-
kWh
$345
80
MMBtu
05: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$1,638
Cost:
$450
- - $1,638 380 -
-
kWh
$1,638
380
MMBtu
06: 2.8113 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER Savings:
$40,497
Cost:
-
- - $40,497 - -
-
kWh
$40,497
-
MMBtu
TOTAL RECOMMENDED Savings:
$43,595
Cost:
$739
$904 23,154 $42,691 509 $904
23,154
kWh
$42,691
509
MMBtu
TOTAL IMPLEMENTED Savings:
$2,753
Cost:
$739
$904 23,154 $1,849 429 $904
23,154
kWh
$1,849
429
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas