IAC logo
IAC Assessment: KU0334
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: KU0334
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Univ. of Kansas
Assessment Year 1991
Principal Product TOOL STORAGE EQUIPMENT
NAICS n/a
SIC 3469 - Metal Stampings, Nec
Sales $50,000,000-$100,000,000
# of Employees 500
Plant Area (Sq.Ft.) 0
Annual Production 60,000 Pieces
Production Hrs. Annual 5,736
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $452,723 9,068,289 kWh $0.05
Natural Gas $248,989 84,005 MMBtu $2.96
TOTAL ENERGY COSTS $701,712
RECOMMENDED SAVINGS* $61,140 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $61,140
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$10,153
Cost:
$1,800
$10,153 203,400 - - $10,153
203,400
kWh
-
-
MMBtu
02: 2.6223 SCHEDULE USE OF ELEVATORS TO CONSERVE ENERGY Savings:
$336
Cost:
$40
$336 6,741 - - $336
6,741
kWh
-
-
MMBtu
03: 2.2624 USE COLD WASTE WATER TO COOL CHILLER FEED WATER Savings:
$22,062
Cost:
$33,150
$22,062 441,970 - - $22,062
441,970
kWh
-
-
MMBtu
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$3,034
Cost:
$4,200
- - $3,034 1,025 -
-
kWh
$3,034
1,025
MMBtu
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$6,382
Cost:
-
$(-29) (-586) $6,411 2,168 $(-29)
(-586)
kWh
$6,411
2,168
MMBtu
06: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$8,054
Cost:
$16,950
- - $8,054 2,721 -
-
kWh
$8,054
2,721
MMBtu
07: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$10,665
Cost:
$22,600
$10,665 128,370 - - $10,665
128,370
kWh
-
-
MMBtu
08: 2.6232 INSTALL SET-BACK TIMERS Savings:
$454
Cost:
$120
$454 9,086 - - $454
9,086
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$61,140
Cost:
$78,860
$43,641 788,981 $17,499 5,914 $43,641
788,981
kWh
$17,499
5,914
MMBtu
TOTAL IMPLEMENTED Savings:
$61,140
Cost:
$78,860
$43,641 788,981 $17,499 5,914 $43,641
788,981
kWh
$17,499
5,914
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas