IAC logo
IAC Assessment: KU0339
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: KU0339
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Univ. of Kansas
Assessment Year 1991
Principal Product SANDERS & GRINDERS
NAICS n/a
SIC 3546 - Power-driven Handtools
Sales $10,000,000-$50,000,000
# of Employees 100
Plant Area (Sq.Ft.) 0
Annual Production 200 Pieces
Production Hrs. Annual 4,032
Location (State) KS
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $64,235 1,175,850 kWh $0.05
Natural Gas $13,869 3,175 MMBtu $4.37
TOTAL ENERGY COSTS $78,104
RECOMMENDED SAVINGS* $8,675 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,675
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7316 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN Savings:
$4,004
Cost:
$700
$2,562 46,893 $1,442 330 - - $2,562
46,893
kWh
$1,442
330
MMBtu
-
-
$
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$1,315
Cost:
$1,860
- - $1,315 301 - - -
-
kWh
$1,315
301
MMBtu
-
-
$
03: 2.7211 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS Savings:
$1,071
Cost:
-
$720 13,189 - - $351 - $720
13,189
kWh
-
-
MMBtu
$351
-
$
04: 2.2692 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER Savings:
$1,066
Cost:
$525
$192 3,517 $874 200 - - $192
3,517
kWh
$874
200
MMBtu
-
-
$
05: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$577
Cost:
$350
$96 1,758 $481 110 - - $96
1,758
kWh
$481
110
MMBtu
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$83
Cost:
$119
$83 1,465 - - - - $83
1,465
kWh
-
-
MMBtu
-
-
$
07: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$415
Cost:
-
- - $415 95 - - -
-
kWh
$415
95
MMBtu
-
-
$
08: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$144
Cost:
-
$144 7,620 - - - - $144
7,620
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$8,675
Cost:
$3,554
$3,797 74,442 $4,527 1,036 $351 - $3,797
74,442
kWh
$4,527
1,036
MMBtu
$351
-
$
TOTAL IMPLEMENTED Savings:
$8,675
Cost:
$3,554
$3,797 74,442 $4,527 1,036 $351 - $3,797
74,442
kWh
$4,527
1,036
MMBtu
$351
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes