Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Univ. of Kansas
Assessment Year 1992
Principal Product GIFT WRAP GRAVURE PRINT
NAICS n/a
SIC 2754 - Commercial Printing, Gravure
Sales $100,000,000-$500,000,000
# of Employees 220
Plant Area (Sq.Ft.) 0
Annual Production 1,179,320 Pieces
Production Hrs. Annual 6,120
Location (State) KS
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $555,854 13,045,135 kWh $0.04
Natural Gas $235,212 120,622 MMBtu $1.95
TOTAL ENERGY COSTS $791,066
RECOMMENDED SAVINGS* $43,919 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $15,372
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.2443 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR Savings:
$11,070
Cost:
$61,560
$(-2,808) (-65,944) $13,878 7,117 $(-2,808)
(-65,944)
kWh
$13,878
7,117
MMBtu
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$7,467
Cost:
$22,400
$7,467 175,557 - - $7,467
175,557
kWh
-
-
MMBtu
03: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE Savings:
$7,388
Cost:
$45,000
$7,388 173,505 - - $7,388
173,505
kWh
-
-
MMBtu
04: 2.7229 AIR CONDITION ONLY SPACE NECESSARY Savings:
$6,390
Cost:
$34,000
$6,390 150,059 - - $6,390
150,059
kWh
-
-
MMBtu
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$5,891
Cost:
$1,000
$(-37) (-879) $5,928 3,040 $(-37)
(-879)
kWh
$5,928
3,040
MMBtu
06: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$3,760
Cost:
$20,620
- - $3,760 1,928 -
-
kWh
$3,760
1,928
MMBtu
07: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$517
Cost:
$150
- - $517 265 -
-
kWh
$517
265
MMBtu
08: 2.6232 INSTALL SET-BACK TIMERS Savings:
$1,099
Cost:
$1,050
$1,099 25,791 - - $1,099
25,791
kWh
-
-
MMBtu
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$175
Cost:
$1,471
$175 4,103 - - $175
4,103
kWh
-
-
MMBtu
10: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$162
Cost:
$600
$162 3,810 - - $162
3,810
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$43,919
Cost:
$187,851
$19,836 466,002 $24,083 12,350 $19,836
466,002
kWh
$24,083
12,350
MMBtu
TOTAL IMPLEMENTED Savings:
$15,372
Cost:
$67,550
$14,855 349,062 $517 265 $14,855
349,062
kWh
$517
265
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas