IAC logo
IAC Assessment: KU0391
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: KU0391
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Univ. of Kansas
Assessment Year 1993
Principal Product BIB OVERALLS
NAICS n/a
SIC 2326 - Men's and Boys' Work Clothing
Sales $5,000,000-$10,000,000
# of Employees 132
Plant Area (Sq.Ft.) 0
Annual Production 377,000 Pieces
Production Hrs. Annual 1,920
Location (State) KS
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $54,856 503,810 kWh $0.11
Natural Gas $4,311 946 MMBtu $4.56
TOTAL ENERGY COSTS $59,167
RECOMMENDED SAVINGS* $9,241 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,130
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$3,692
Cost:
$4,410
$3,542 32,532 $150 33 - - $3,542
32,532
kWh
$150
33
MMBtu
-
-
$
03: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$2,070
Cost:
$1,281
$2,521 23,154 $(-451) (-99) - - $2,521
23,154
kWh
$(-451)
(-99)
MMBtu
-
-
$
04: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$1,732
Cost:
$1,316
$2,106 19,343 $(-374) (-82) - - $2,106
19,343
kWh
$(-374)
(-82)
MMBtu
-
-
$
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,181
Cost:
$1,200
$1,181 10,844 - - - - $1,181
10,844
kWh
-
-
MMBtu
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$46
Cost:
-
$135 1,172 - - $(-89) - $135
1,172
kWh
-
-
MMBtu
$(-89)
-
$
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$128
Cost:
$350
$128 1,172 - - - - $128
1,172
kWh
-
-
MMBtu
-
-
$
08: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$292
Cost:
$70
- - $292 64 - - -
-
kWh
$292
64
MMBtu
-
-
$
09: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$100
Cost:
$88
- - $100 22 - - -
-
kWh
$100
22
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$9,241
Cost:
$8,715
$9,613 88,217 $(-283) (-62) $(-89) - $9,613
88,217
kWh
$(-283)
(-62)
MMBtu
$(-89)
-
$
TOTAL IMPLEMENTED Savings:
$4,130
Cost:
$4,568
$3,677 33,704 $542 119 $(-89) - $3,677
33,704
kWh
$542
119
MMBtu
$(-89)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes