Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Univ. of Kansas |
---|---|
Assessment Year | 1994 |
Principal Product | Concrete Finishing Tools |
NAICS | n/a |
SIC | 3423 - Hand And Edge Tools, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 108,000 |
Annual Production | 2,500,000 Pieces |
Production Hrs. Annual | 4,693 |
Location (State) | KS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $124,922 | 2,105,510 | kWh | $0.06 |
Natural Gas | $40,215 | 11,048 | MMBtu | $3.64 |
TOTAL ENERGY COSTS | $165,137 | |||
RECOMMENDED SAVINGS* | $22,348 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $12,081 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Natural Gas | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $6,707 Cost: $12,000 |
$3,721 | 62,720 | $2,986 | 846 | - | - | - | - |
$3,721 62,720 kWh |
$2,986 846 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $6,145 Cost: $14,000 |
$8,312 | 140,094 | $(-2,167) | (-614) | - | - | - | - |
$8,312 140,094 kWh |
$(-2,167) (-614) MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,604 Cost: $2,150 |
$2,604 | 43,962 | - | - | - | - | - | - |
$2,604 43,962 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $643 Cost: $120 |
$643 | 10,844 | - | - | - | - | - | - |
$643 10,844 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,695 Cost: $12,025 |
$4,042 | 67,995 | - | - | $1,653 | - | - | - |
$4,042 67,995 kWh |
- - MMBtu |
$1,653 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $241 Cost: $150 |
$155 | 2,638 | - | - | - | - | $86 | - |
$155 2,638 kWh |
- - MMBtu |
- - $ |
$86 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $313 Cost: $377 |
$313 | 5,275 | - | - | - | - | - | - |
$313 5,275 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $22,348 Cost: $40,822 |
$19,790 | 333,528 | $819 | 232 | $1,653 | - | $86 | - | $19,790 333,528 kWh |
$819 232 MMBtu |
$1,653 - $ |
$86 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $12,081 Cost: $26,175 |
$12,509 | 210,727 | $(-2,167) | (-614) | $1,653 | - | $86 | - | $12,509 210,727 kWh |
$(-2,167) (-614) MMBtu |
$1,653 - $ |
$86 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Natural Gas | Administrative Changes | Ancillary Material Cost |