Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Univ. of Kansas |
---|---|
Assessment Year | 1995 |
Principal Product | Point of purchase displays |
NAICS | n/a |
SIC | 2542 - Partitions And Fixtures, Except Wood |
Sales | $5,000,000-$10,000,000 |
# of Employees | 350 |
Plant Area (Sq.Ft.) | 303,886 |
Annual Production | 41,000 Thousand Feet |
Production Hrs. Annual | 6,600 |
Location (State) | KS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $174,404 | 3,201,641 | kWh | $0.05 |
Natural Gas | $47,886 | 9,545 | MMBtu | $5.02 |
TOTAL ENERGY COSTS | $227,581 | |||
RECOMMENDED SAVINGS* | $28,825 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,540 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Water Disposal | Administrative Changes | Electricity Usage | Natural Gas | Water Disposal | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $11,232 Cost: $34,320 |
$9,087 | 166,764 | - | - | - | - | $2,145 | - |
$9,087 166,764 kWh |
- - MMBtu |
- - Tgal |
$2,145 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $3,753 Cost: $420 |
$3,753 | 68,875 | - | - | - | - | - | - |
$3,753 68,875 kWh |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,214 Cost: $1,970 |
$1,214 | 22,274 | - | - | - | - | - | - |
$1,214 22,274 kWh |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $391 Cost: $660 |
$160 | 2,931 | - | - | - | - | $231 | - |
$160 2,931 kWh |
- - MMBtu |
- - Tgal |
$231 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4155 METER WASTE WATER |
Savings: $2,463 Cost: $500 |
- | - | - | - | $2,463 | - | - | - |
- - kWh |
- - MMBtu |
$2,463 - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,821 Cost: $232 |
$1,821 | 33,411 | - | - | - | - | - | - |
$1,821 33,411 kWh |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,310 Cost: $180 |
$1,310 | 24,033 | - | - | - | - | - | - |
$1,310 24,033 kWh |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,246 Cost: $165 |
$1,246 | 22,860 | - | - | - | - | - | - |
$1,246 22,860 kWh |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,004 Cost: $2,184 |
- | - | $1,004 | 200 | - | - | - | - |
- - kWh |
$1,004 200 MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.4113 TREAT AND REUSE RINSE WATERS |
Savings: $990 Cost: $3,850 |
- | - | - | - | $990 | 495,000 | - | - |
- - kWh |
- - MMBtu |
$990 495,000 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,417 Cost: $4,200 |
$2,417 | - | - | - | - | - | - | - |
$2,417 - kWh |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $984 Cost: $150 |
- | - | $984 | 196 | - | - | - | - |
- - kWh |
$984 196 MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $28,825 Cost: $48,831 |
$21,008 | 341,148 | $1,988 | 396 | $3,453 | 495,000 | $2,376 | - | $21,008 341,148 kWh |
$1,988 396 MMBtu |
$3,453 495,000 Tgal |
$2,376 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,540 Cost: $495 |
$2,556 | 46,893 | $984 | 196 | - | - | - | - | $2,556 46,893 kWh |
$984 196 MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Water Disposal | Administrative Changes | Electricity Usage | Natural Gas | Water Disposal | Administrative Changes |