Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Univ. of Kansas |
---|---|
Assessment Year | 2000 |
Principal Product | coffee |
NAICS | n/a |
SIC | 2095 - Roasted Coffee |
Sales | $100,000,000-$500,000,000 |
# of Employees | 235 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 100,000,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $489,342 | 13,619,871 | kWh | $0.04 |
Electricity Demand | $227,526 | 26,976 | kW-months/year | $8.43 |
Natural Gas | $703,564 | 232,065 | MMBtu | $3.03 |
Other Energy | $125,455 | 9,658 | MMBtu | $12.99 |
TOTAL ENERGY COSTS | $1,656,222 | |||
RECOMMENDED SAVINGS* | $313,270 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $15,700 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Energy | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Energy | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $163,360 Cost: $135,000 |
- | - | - | - | $163,360 | 54,090 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$163,360 54,090 MMBtu |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $44,700 Cost: $30,000 |
- | - | - | - | $44,700 | 14,800 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$44,700 14,800 MMBtu |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2211 USE OPTIMUM TEMPERATURE |
Savings: $15,700 Cost: $20,000 |
- | - | - | - | $15,700 | 5,200 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$15,700 5,200 MMBtu |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $2,800 Cost: - |
- | - | $6,800 | 585 | - | - | - | - | - | - | $(-4,000) | - |
- - kWh |
$6,800 585 kW-months/year |
- - MMBtu |
- - MMBtu |
- - Tgal |
$(-4,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $9,070 Cost: $5,750 |
$(-290) | (-11,723) | $(-380) | (-32) | - | - | - | - | $9,740 | 5,781,600 | - | - |
$(-290) (-11,723) kWh |
$(-380) (-32) kW-months/year |
- - MMBtu |
- - MMBtu |
$9,740 5,781,600 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1392 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE |
Savings: $77,640 Cost: $85,000 |
- | - | - | - | $(-47,810) | (-10,673) | $125,450 | 9,658 | - | - | - | - |
- - kWh |
- - kW-months/year |
$(-47,810) (-10,673) MMBtu |
$125,450 9,658 MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $313,270 Cost: $275,750 |
$(-290) | (-11,723) | $6,420 | 553 | $175,950 | 63,417 | $125,450 | 9,658 | $9,740 | 5,781,600 | $(-4,000) | - | $(-290) (-11,723) kWh |
$6,420 553 kW-months/year |
$175,950 63,417 MMBtu |
$125,450 9,658 MMBtu |
$9,740 5,781,600 Tgal |
$(-4,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $15,700 Cost: $20,000 |
- | - | - | - | $15,700 | 5,200 | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
$15,700 5,200 MMBtu |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Energy | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Energy | Water Disposal | Personnel Changes |