Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2002 |
Principal Product | Automobile Bearings |
NAICS | n/a |
SIC | 3462 - Iron And Steel Forgings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 268,000 |
Annual Production | 3,126,000 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $757,404 | 16,880,946 | kWh | $0.04 |
Electricity Demand | $223,035 | 35,426 | kW-months/year | $6.30 |
Natural Gas | $450,560 | 57,490 | MMBtu | $7.84 |
TOTAL ENERGY COSTS | $1,430,999 | |||
RECOMMENDED SAVINGS* | $147,149 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $27,506 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $5,934 Cost: $150 |
$5,027 | 100,740 | $907 | 144 | - | - | - | - |
$5,027 100,740 kWh |
$907 144 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $583 Cost: $180 |
- | - | - | - | $583 | 74 | - | - |
- - kWh |
- - kW-months/year |
$583 74 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $2,040 Cost: - |
- | - | - | - | - | - | $2,040 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$2,040 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1116 IMPROVE COMBUSTION CONTROL CAPABILITY |
Savings: $8,789 Cost: $1,000 |
- | - | - | - | $8,789 | 1,121 | - | - |
- - kWh |
- - kW-months/year |
$8,789 1,121 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $16,677 Cost: - |
$10,567 | 235,338 | $6,110 | 970 | - | - | - | - |
$10,567 235,338 kWh |
$6,110 970 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4312 IMPROVE LUBRICATION PRACTICES |
Savings: $7,373 Cost: $400 |
$7,132 | 158,832 | $241 | 38 | - | - | - | - |
$7,132 158,832 kWh |
$241 38 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7496 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE |
Savings: $105,753 Cost: $60,000 |
$57,374 | 1,277,816 | $48,379 | 7,679 | - | - | - | - |
$57,374 1,277,816 kWh |
$48,379 7,679 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $147,149 Cost: $61,730 |
$80,100 | 1,772,726 | $55,637 | 8,831 | $9,372 | 1,195 | $2,040 | - | $80,100 1,772,726 kWh |
$55,637 8,831 kW-months/year |
$9,372 1,195 MMBtu |
$2,040 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $27,506 Cost: $1,000 |
$10,567 | 235,338 | $6,110 | 970 | $8,789 | 1,121 | $2,040 | - | $10,567 235,338 kWh |
$6,110 970 kW-months/year |
$8,789 1,121 MMBtu |
$2,040 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal |