Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2002 |
Principal Product | Solar Cells |
NAICS | n/a |
SIC | 3674 - Semiconductors And Related Devices |
Sales | $50,000,000-$100,000,000 |
# of Employees | 440 |
Plant Area (Sq.Ft.) | 130,000 |
Annual Production | 9,000,000 Pieces |
Production Hrs. Annual | 7,072 |
Location (State) | DE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $388,317 | 11,066,350 | kWh | $0.04 |
Electricity Demand | $242,015 | 21,887 | kW-months/year | $11.06 |
Natural Gas | $18,816 | 2,018 | MMBtu | $9.32 |
TOTAL ENERGY COSTS | $649,148 | |||
RECOMMENDED SAVINGS* | $89,673 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $70,358 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $10,955 Cost: $2,500 |
- | - | $10,955 | 85 | - | - |
- - kWh |
$10,955 85 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,721 Cost: $2,500 |
$2,136 | 60,867 | $1,585 | 148 | - | - |
$2,136 60,867 kWh |
$1,585 148 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,451 Cost: - |
$2,451 | 69,816 | - | - | - | - |
$2,451 69,816 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2514 COVER OPEN TANKS |
Savings: $4,639 Cost: $12,000 |
- | - | - | - | $4,639 | 497 |
- - kWh |
- - kW-months/year |
$4,639 497 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,792 Cost: - |
$1,654 | 47,132 | $1,138 | 106 | - | - |
$1,654 47,132 kWh |
$1,138 106 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4312 IMPROVE LUBRICATION PRACTICES |
Savings: $1,066 Cost: $200 |
$701 | 19,966 | $365 | 34 | - | - |
$701 19,966 kWh |
$365 34 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $62,395 Cost: $12,000 |
- | - | $62,395 | 423 | - | - |
- - kWh |
$62,395 423 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2611 MODERATE COOLING TOWER OUTLET TEMPERATURE |
Savings: $1,654 Cost: $630 |
$1,654 | 47,125 | - | - | - | - |
$1,654 47,125 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $89,673 Cost: $29,830 |
$8,596 | 244,906 | $76,438 | 796 | $4,639 | 497 | $8,596 244,906 kWh |
$76,438 796 kW-months/year |
$4,639 497 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $70,358 Cost: $12,830 |
$6,460 | 184,039 | $63,898 | 563 | - | - | $6,460 184,039 kWh |
$63,898 563 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |