Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2002 |
Principal Product | Power Transmission Equipment |
NAICS | n/a |
SIC | 3568 - Power Transmission Equipment, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 350 |
Plant Area (Sq.Ft.) | 415,454 |
Annual Production | 33,000 Tons |
Production Hrs. Annual | 6,500 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $998,560 | 27,347,634 | kWh | $0.04 |
Electricity Demand | $366,883 | 36,466 | kW-months/year | $10.06 |
Natural Gas | $490,000 | 61,936 | MMBtu | $7.91 |
TOTAL ENERGY COSTS | $1,855,443 | |||
RECOMMENDED SAVINGS* | $142,585 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $20,714 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2426 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR |
Savings: $54,428 Cost: $30,000 |
- | - | - | - | $54,428 | 7,433 |
- - kWh |
- - kW-months/year |
$54,428 7,433 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $20,604 Cost: $31,000 |
- | - | - | - | $20,604 | 2,604 |
- - kWh |
- - kW-months/year |
$20,604 2,604 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $43,767 Cost: $25,000 |
- | - | $43,767 | 4,706 | - | - |
- - kWh |
$43,767 4,706 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $14,099 Cost: $11,750 |
- | - | - | - | $14,099 | 570 |
- - kWh |
- - kW-months/year |
$14,099 570 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $6,615 Cost: $3,000 |
$2,569 | 101,539 | $4,046 | 435 | - | - |
$2,569 101,539 kWh |
$4,046 435 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4238 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING |
Savings: $370 Cost: $700 |
$112 | 4,421 | $258 | 28 | - | - |
$112 4,421 kWh |
$258 28 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,702 Cost: - |
$1,049 | 41,463 | $1,653 | 178 | - | - |
$1,049 41,463 kWh |
$1,653 178 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $142,585 Cost: $101,450 |
$3,730 | 147,423 | $49,724 | 5,347 | $89,131 | 10,607 | $3,730 147,423 kWh |
$49,724 5,347 kW-months/year |
$89,131 10,607 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $20,714 Cost: $14,750 |
$2,569 | 101,539 | $4,046 | 435 | $14,099 | 570 | $2,569 101,539 kWh |
$4,046 435 kW-months/year |
$14,099 570 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |