IAC logo
IAC Assessment: LE0137
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: LE0137
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Lehigh University
Assessment Year 2002
Principal Product Power Transmission Equipment
NAICS n/a
SIC 3568 - Power Transmission Equipment, Nec
Sales $50,000,000-$100,000,000
# of Employees 350
Plant Area (Sq.Ft.) 415,454
Annual Production 33,000 Tons
Production Hrs. Annual 6,500
Location (State) PA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $998,560 27,347,634 kWh $0.04
Electricity Demand $366,883 36,466 kW-months/year $10.06
Natural Gas $490,000 61,936 MMBtu $7.91
TOTAL ENERGY COSTS $1,855,443
RECOMMENDED SAVINGS* $142,585 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $20,714
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.2426 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR Savings:
$54,428
Cost:
$30,000
- - - - $54,428 7,433 -
-
kWh
-
-
kW-months/year
$54,428
7,433
MMBtu
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$20,604
Cost:
$31,000
- - - - $20,604 2,604 -
-
kWh
-
-
kW-months/year
$20,604
2,604
MMBtu
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$43,767
Cost:
$25,000
- - $43,767 4,706 - - -
-
kWh
$43,767
4,706
kW-months/year
-
-
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$14,099
Cost:
$11,750
- - - - $14,099 570 -
-
kWh
-
-
kW-months/year
$14,099
570
MMBtu
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$6,615
Cost:
$3,000
$2,569 101,539 $4,046 435 - - $2,569
101,539
kWh
$4,046
435
kW-months/year
-
-
MMBtu
06: 2.4238 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING Savings:
$370
Cost:
$700
$112 4,421 $258 28 - - $112
4,421
kWh
$258
28
kW-months/year
-
-
MMBtu
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,702
Cost:
-
$1,049 41,463 $1,653 178 - - $1,049
41,463
kWh
$1,653
178
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$142,585
Cost:
$101,450
$3,730 147,423 $49,724 5,347 $89,131 10,607 $3,730
147,423
kWh
$49,724
5,347
kW-months/year
$89,131
10,607
MMBtu
TOTAL IMPLEMENTED Savings:
$20,714
Cost:
$14,750
$2,569 101,539 $4,046 435 $14,099 570 $2,569
101,539
kWh
$4,046
435
kW-months/year
$14,099
570
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas