Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2004 |
Principal Product | Heating Appliances |
NAICS | 333414 - Heating Equipment (except Warm Air Furnaces) Manufacturing |
SIC | 3433 - Heating Equipment, Except Electric |
Sales | $10,000,000-$50,000,000 |
# of Employees | 135 |
Plant Area (Sq.Ft.) | 117,000 |
Annual Production | 12,000 Pieces |
Production Hrs. Annual | 2,040 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $82,066 | 1,708,500 | kWh | $0.05 |
Electricity Demand | $35,436 | 5,106 | kW-months/year | $6.94 |
Natural Gas | $13,856 | 1,076 | MMBtu | $12.88 |
TOTAL ENERGY COSTS | $131,358 | |||
RECOMMENDED SAVINGS* | $18,700 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,443 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Coal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | LPG | Coal | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7314 REDUCE VENTILATION AIR |
Savings: $10,362 Cost: $942 |
- | - | - | - | $10,362 | 805 | - | - | - | - |
- - kWh |
- - kW-months/year |
$10,362 805 MMBtu |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $2,781 Cost: - |
- | - | - | - | - | - | - | - | $2,781 | 36,032 |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
$2,781 36,032 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,423 Cost: $89 |
$999 | 20,808 | $424 | 61 | - | - | - | - | - | - |
$999 20,808 kWh |
$424 61 kW-months/year |
- - MMBtu |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,185 Cost: - |
$1,185 | 24,695 | - | - | - | - | - | - | - | - |
$1,185 24,695 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $960 Cost: $750 |
- | - | - | - | - | - | $960 | 300 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$960 300 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $573 Cost: $500 |
$185 | 3,859 | $388 | 56 | - | - | - | - | - | - |
$185 3,859 kWh |
$388 56 kW-months/year |
- - MMBtu |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $532 Cost: - |
- | - | $532 | 77 | - | - | - | - | - | - |
- - kWh |
$532 77 kW-months/year |
- - MMBtu |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $451 Cost: - |
- | - | - | - | - | - | - | - | $451 | 110 |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
$451 110 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $218 Cost: $279 |
- | - | - | - | - | - | $218 | 68 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$218 68 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $215 Cost: - |
$170 | 3,539 | $45 | 6 | - | - | - | - | - | - |
$170 3,539 kWh |
$45 6 kW-months/year |
- - MMBtu |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $18,700 Cost: $2,560 |
$2,539 | 52,901 | $1,389 | 200 | $10,362 | 805 | $1,178 | 368 | $3,232 | 36,142 | $2,539 52,901 kWh |
$1,389 200 kW-months/year |
$10,362 805 MMBtu |
$1,178 368 MMBtu |
$3,232 36,142 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,443 Cost: $589 |
$1,354 | 28,206 | $857 | 123 | - | - | - | - | $3,232 | 36,142 | $1,354 28,206 kWh |
$857 123 kW-months/year |
- - MMBtu |
- - MMBtu |
$3,232 36,142 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Coal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | LPG | Coal | Solid Waste (non-haz) |