Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2006 |
Principal Product | Aluminum organic chemicals |
NAICS | 325199 - All Other Basic Organic Chemical Manufacturing |
SIC | 2869 - Industrial Organic Chemicals, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 21 |
Plant Area (Sq.Ft.) | 20,168 |
Annual Production | 2,147,483,647 Pounds |
Production Hrs. Annual | 7,344 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $59,925 | 891,800 | kWh | $0.07 |
Electricity Demand | $8,049 | 1,845 | kW-months/year | $4.36 |
Fuel Oil #2 | $122,291 | 10,878 | MMBtu | $11.24 |
TOTAL ENERGY COSTS | $190,265 | |||
RECOMMENDED SAVINGS* | $312,863 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $36,883 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #2 | Primary Raw Material | Increase in Production | Electricity Usage | Electricity Demand | Fuel Oil #2 | Primary Raw Material | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1224 REPLACE BOILER |
Savings: $115,080 Cost: $223,000 |
- | - | - | - | $115,080 | 2,380 | - | - | - | - |
- - kWh |
- - kW-months/year |
$115,080 2,380 MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.1172 REVISE RAW MATERIAL SPECS |
Savings: $106,250 Cost: $60,000 |
- | - | - | - | - | - | - | - | $106,250 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$106,250 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $26,312 Cost: $16,000 |
- | - | - | - | $26,312 | 2,341 | - | - | - | - |
- - kWh |
- - kW-months/year |
$26,312 2,341 MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.212 ADOPT IN-HOUSE MATERIAL GENERATION |
Savings: $24,012 Cost: $20,000 |
- | - | - | - | - | - | $24,012 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$24,012 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $23,245 Cost: $15,000 |
- | - | - | - | $23,245 | 2,068 | - | - | - | - |
- - kWh |
- - kW-months/year |
$23,245 2,068 MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $11,646 Cost: $2,500 |
- | - | - | - | $11,646 | 1,036 | - | - | - | - |
- - kWh |
- - kW-months/year |
$11,646 1,036 MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $1,225 Cost: $1,152 |
- | - | - | - | $1,225 | 109 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,225 109 MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,181 Cost: $300 |
$1,181 | 17,626 | - | - | - | - | - | - | - | - |
$1,181 17,626 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,912 Cost: $3,722 |
$3,533 | 52,710 | $379 | 87 | - | - | - | - | - | - |
$3,533 52,710 kWh |
$379 87 kW-months/year |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $312,863 Cost: $341,674 |
$4,714 | 70,336 | $379 | 87 | $177,508 | 7,934 | $24,012 | - | $106,250 | - | $4,714 70,336 kWh |
$379 87 kW-months/year |
$177,508 7,934 MMBtu |
$24,012 - $ |
$106,250 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $36,883 Cost: $23,652 |
- | - | - | - | $12,871 | 1,145 | $24,012 | - | - | - | - - kWh |
- - kW-months/year |
$12,871 1,145 MMBtu |
$24,012 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #2 | Primary Raw Material | Increase in Production | Electricity Usage | Electricity Demand | Fuel Oil #2 | Primary Raw Material | Increase in Production |