Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Lehigh University
Assessment Year 2010
Principal Product Vinyl film
NAICS 326113 - Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing
SIC 3083 - Laminated Plastics Plate & Sheet
Sales $10,000,000-$50,000,000
# of Employees 154
Plant Area (Sq.Ft.) 180,000
Annual Production 21,000,000 Units
Production Hrs. Annual 6,000
Location (State) PA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $737,130 14,397,600 kWh $0.05
Electricity Demand $264,643 30,770 kW-months/year $8.60
Natural Gas $948,636 103,342 MMBtu $9.18
TOTAL ENERGY COSTS $1,950,409
RECOMMENDED SAVINGS* $668,174 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $105,126
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.1224 REPLACE BOILER Savings:
$284,580
Cost:
$500,000
- - - - $284,580 31,000 - - -
-
kWh
-
-
kW-months/year
$284,580
31,000
MMBtu
-
-
$
02: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER Savings:
$185,253
Cost:
$118,000
- - - - $185,253 20,180 - - -
-
kWh
-
-
kW-months/year
$185,253
20,180
MMBtu
-
-
$
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$57,617
Cost:
$13,469
$44,786 878,173 $12,831 1,492 - - - - $44,786
878,173
kWh
$12,831
1,492
kW-months/year
-
-
MMBtu
-
-
$
04: 2.2692 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER Savings:
$28,496
Cost:
$10,000
$28,496 558,742 - - - - - - $28,496
558,742
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
05: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER Savings:
$24,299
Cost:
$75,000
- - - - $24,299 2,647 - - -
-
kWh
-
-
kW-months/year
$24,299
2,647
MMBtu
-
-
$
06: 2.2113 REPAIR OR REPLACE STEAM TRAPS Savings:
$23,321
Cost:
$4,200
- - - - $23,321 2,540 - - -
-
kWh
-
-
kW-months/year
$23,321
2,540
MMBtu
-
-
$
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$12,721
Cost:
$22,000
- - - - $12,721 1,385 - - -
-
kWh
-
-
kW-months/year
$12,721
1,385
MMBtu
-
-
$
08: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES Savings:
$11,375
Cost:
$100,000
$1,353 26,541 $22 3 - - $10,000 - $1,353
26,541
kWh
$22
3
kW-months/year
-
-
MMBtu
$10,000
-
$
09: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES Savings:
$8,386
Cost:
$8,000
$6,331 124,153 $2,055 239 - - - - $6,331
124,153
kWh
$2,055
239
kW-months/year
-
-
MMBtu
-
-
$
10: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$8,358
Cost:
$870
$8,358 163,888 - - - - - - $8,358
163,888
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
11: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$7,938
Cost:
$3,000
- - $7,938 923 - - - - -
-
kWh
$7,938
923
kW-months/year
-
-
MMBtu
-
-
$
12: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$6,001
Cost:
$4,500
$4,917 96,419 $1,084 126 - - - - $4,917
96,419
kWh
$1,084
126
kW-months/year
-
-
MMBtu
-
-
$
13: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$4,550
Cost:
$2,440
$3,432 67,371 $1,118 130 - - - - $3,432
67,371
kWh
$1,118
130
kW-months/year
-
-
MMBtu
-
-
$
14: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$4,029
Cost:
$20,000
- - - - $4,029 439 - - -
-
kWh
-
-
kW-months/year
$4,029
439
MMBtu
-
-
$
15: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,097
Cost:
$2,035
$1,097 21,504 - - - - - - $1,097
21,504
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
16: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$153
Cost:
$1,000
- - - - $153 17 - - -
-
kWh
-
-
kW-months/year
$153
17
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$668,174
Cost:
$884,514
$98,770 1,936,791 $25,048 2,913 $534,356 58,208 $10,000 - $98,770
1,936,791
kWh
$25,048
2,913
kW-months/year
$534,356
58,208
MMBtu
$10,000
-
$
TOTAL IMPLEMENTED Savings:
$105,126
Cost:
$48,514
$62,590 1,227,355 $15,033 1,748 $27,503 2,996 - - $62,590
1,227,355
kWh
$15,033
1,748
kW-months/year
$27,503
2,996
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost