IAC logo
IAC Assessment: LE0309
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: LE0309
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Lehigh University
Assessment Year 2010
Principal Product fluid milk
NAICS 311511 - Fluid Milk Manufacturing
SIC 2026 - Fluid Milk
Sales $1,000,000-$5,000,000
# of Employees 252
Plant Area (Sq.Ft.) 74,000
Annual Production 62,500 Thousand Gallons
Production Hrs. Annual 5,616
Location (State) PA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $532,726 8,462,709 kWh $0.06
Electricity Demand $159,296 22,856 kW-months/year $6.97
Natural Gas $452,690 49,648 MMBtu $9.12
TOTAL ENERGY COSTS $1,144,712
RECOMMENDED SAVINGS* $305,297 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $88,267
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR Savings:
$189,768
Cost:
$90,000
$149,907 2,379,476 $39,861 5,719 - - - - $149,907
2,379,476
kWh
$39,861
5,719
kW-months/year
-
-
MMBtu
-
-
$
02: 2.2511 INSULATE BARE EQUIPMENT Savings:
$23,403
Cost:
$5,772
- - - - $23,403 2,566 - - -
-
kWh
-
-
kW-months/year
$23,403
2,566
MMBtu
-
-
$
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$21,770
Cost:
$250
$10,453 165,927 - - $11,317 1,241 - - $10,453
165,927
kWh
-
-
kW-months/year
$11,317
1,241
MMBtu
-
-
$
04: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR Savings:
$16,145
Cost:
$20,000
$12,751 202,393 $3,394 487 - - - - $12,751
202,393
kWh
$3,394
487
kW-months/year
-
-
MMBtu
-
-
$
05: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT Savings:
$11,117
Cost:
$30,000
- - - - $11,117 1,219 - - -
-
kWh
-
-
kW-months/year
$11,117
1,219
MMBtu
-
-
$
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$6,925
Cost:
-
$5,687 90,276 $1,238 178 - - - - $5,687
90,276
kWh
$1,238
178
kW-months/year
-
-
MMBtu
-
-
$
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$6,657
Cost:
$1,000
$5,259 83,478 $1,398 200 - - - - $5,259
83,478
kWh
$1,398
200
kW-months/year
-
-
MMBtu
-
-
$
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$5,494
Cost:
$40
$5,494 87,208 - - - - - - $5,494
87,208
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$24,018
Cost:
$2,431
$17,331 275,089 $4,609 661 - - $2,078 - $17,331
275,089
kWh
$4,609
661
kW-months/year
-
-
MMBtu
$2,078
-
$
TOTAL RECOMMENDED Savings:
$305,297
Cost:
$149,493
$206,882 3,283,847 $50,500 7,245 $45,837 5,026 $2,078 - $206,882
3,283,847
kWh
$50,500
7,245
kW-months/year
$45,837
5,026
MMBtu
$2,078
-
$
TOTAL IMPLEMENTED Savings:
$88,267
Cost:
$9,493
$44,224 701,978 $7,245 1,039 $34,720 3,807 $2,078 - $44,224
701,978
kWh
$7,245
1,039
kW-months/year
$34,720
3,807
MMBtu
$2,078
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost