Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2010 |
Principal Product | fluid milk |
NAICS | 311511 - Fluid Milk Manufacturing |
SIC | 2026 - Fluid Milk |
Sales | $1,000,000-$5,000,000 |
# of Employees | 252 |
Plant Area (Sq.Ft.) | 74,000 |
Annual Production | 62,500 Thousand Gallons |
Production Hrs. Annual | 5,616 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $532,726 | 8,462,709 | kWh | $0.06 |
Electricity Demand | $159,296 | 22,856 | kW-months/year | $6.97 |
Natural Gas | $452,690 | 49,648 | MMBtu | $9.12 |
TOTAL ENERGY COSTS | $1,144,712 | |||
RECOMMENDED SAVINGS* | $305,297 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $88,267 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $189,768 Cost: $90,000 |
$149,907 | 2,379,476 | $39,861 | 5,719 | - | - | - | - |
$149,907 2,379,476 kWh |
$39,861 5,719 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $23,403 Cost: $5,772 |
- | - | - | - | $23,403 | 2,566 | - | - |
- - kWh |
- - kW-months/year |
$23,403 2,566 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $21,770 Cost: $250 |
$10,453 | 165,927 | - | - | $11,317 | 1,241 | - | - |
$10,453 165,927 kWh |
- - kW-months/year |
$11,317 1,241 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $16,145 Cost: $20,000 |
$12,751 | 202,393 | $3,394 | 487 | - | - | - | - |
$12,751 202,393 kWh |
$3,394 487 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $11,117 Cost: $30,000 |
- | - | - | - | $11,117 | 1,219 | - | - |
- - kWh |
- - kW-months/year |
$11,117 1,219 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $6,925 Cost: - |
$5,687 | 90,276 | $1,238 | 178 | - | - | - | - |
$5,687 90,276 kWh |
$1,238 178 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,657 Cost: $1,000 |
$5,259 | 83,478 | $1,398 | 200 | - | - | - | - |
$5,259 83,478 kWh |
$1,398 200 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $5,494 Cost: $40 |
$5,494 | 87,208 | - | - | - | - | - | - |
$5,494 87,208 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $24,018 Cost: $2,431 |
$17,331 | 275,089 | $4,609 | 661 | - | - | $2,078 | - |
$17,331 275,089 kWh |
$4,609 661 kW-months/year |
- - MMBtu |
$2,078 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $305,297 Cost: $149,493 |
$206,882 | 3,283,847 | $50,500 | 7,245 | $45,837 | 5,026 | $2,078 | - | $206,882 3,283,847 kWh |
$50,500 7,245 kW-months/year |
$45,837 5,026 MMBtu |
$2,078 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $88,267 Cost: $9,493 |
$44,224 | 701,978 | $7,245 | 1,039 | $34,720 | 3,807 | $2,078 | - | $44,224 701,978 kWh |
$7,245 1,039 kW-months/year |
$34,720 3,807 MMBtu |
$2,078 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost |