Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Lehigh University
Assessment Year 2012
Principal Product Auto Parts
NAICS 423120 - Motor Vehicle Supplies and New Parts Merchant Wholesalers
SIC 3714 - Motor Vehicle Parts And Accessories
Sales $100,000,000-$500,000,000
# of Employees 350
Plant Area (Sq.Ft.) 342,000
Annual Production 500,000 Pieces
Production Hrs. Annual 6,552
Location (State) PA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $294,019 3,648,974 kWh $0.08
Natural Gas $93,426 13,326 MMBtu $7.01
TOTAL ENERGY COSTS $387,445
RECOMMENDED SAVINGS* $137,330 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$9,181
Cost:
$8,250
$9,181 120,797 - - $9,181
120,797
kWh
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$32,208
Cost:
$54,225
$32,208 416,864 - - $32,208
416,864
kWh
-
-
MMBtu
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$953
Cost:
$1,000
$953 12,543 - - $953
12,543
kWh
-
-
MMBtu
04: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$26,676
Cost:
-
$26,676 351,000 - - $26,676
351,000
kWh
-
-
MMBtu
05: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$5,033
Cost:
$5,527
- - $5,033 718 -
-
kWh
$5,033
718
MMBtu
06: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD Savings:
$10,053
Cost:
$13,598
$10,053 127,895 - - $10,053
127,895
kWh
-
-
MMBtu
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,391
Cost:
$1,900
$1,391 18,307 - - $1,391
18,307
kWh
-
-
MMBtu
08: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$16,632
Cost:
$3,000
$4,385 57,693 $12,247 1,747 $4,385
57,693
kWh
$12,247
1,747
MMBtu
09: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$3,535
Cost:
$21,000
$2,974 39,137 $561 80 $2,974
39,137
kWh
$561
80
MMBtu
10: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,096
Cost:
$12,800
$3,096 40,732 - - $3,096
40,732
kWh
-
-
MMBtu
11: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$586
Cost:
$800
$586 7,713 - - $586
7,713
kWh
-
-
MMBtu
12: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$16,429
Cost:
$30,000
$16,429 213,169 - - $16,429
213,169
kWh
-
-
MMBtu
13: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$9,090
Cost:
-
$9,090 119,600 - - $9,090
119,600
kWh
-
-
MMBtu
14: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$262
Cost:
$520
$262 3,450 - - $262
3,450
kWh
-
-
MMBtu
15: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,205
Cost:
$10,010
$2,205 28,304 - - $2,205
28,304
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$137,330
Cost:
$162,630
$119,489 1,557,204 $17,841 2,545 $119,489
1,557,204
kWh
$17,841
2,545
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas