Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Lehigh University
Assessment Year 2015
Principal Product Expanded Polystyrene
NAICS 326140 - Polystyrene Foam Product Manufacturing
SIC 3086 - Plastics Foam Products
Sales $5,000,000-$10,000,000
# of Employees 37
Plant Area (Sq.Ft.) 67,200
Annual Production 61,943,274,000,000 Thousand Feet
Production Hrs. Annual 2,080
Location (State) PA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $38,503 482,400 kWh $0.08
Electricity Demand $13,037 3,110 kW-months/year $4.19
Electricity Fees $1,541 - $ -
Natural Gas $134,899 17,046 MMBtu $7.91
TOTAL ENERGY COSTS $187,980
RECOMMENDED SAVINGS* $29,730 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $15,422
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,031
Cost:
$45
$792 9,898 $239 57 - - $792
9,898
kWh
$239
57
kW-months/year
-
-
MMBtu
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$388
Cost:
$183
$276 3,454 $111 27 - - $276
3,454
kWh
$111
27
kW-months/year
-
-
MMBtu
03: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$5,142
Cost:
$3,000
- - - - $5,142 650 -
-
kWh
-
-
kW-months/year
$5,142
650
MMBtu
04: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$582
Cost:
$343
- - - - $582 74 -
-
kWh
-
-
kW-months/year
$582
74
MMBtu
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$5,751
Cost:
$5,000
- - - - $5,751 727 -
-
kWh
-
-
kW-months/year
$5,751
727
MMBtu
06: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$247
Cost:
$245
$247 3,091 - - - - $247
3,091
kWh
-
-
kW-months/year
-
-
MMBtu
07: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT Savings:
$1,205
Cost:
$1,600
$1,205 15,061 - - - - $1,205
15,061
kWh
-
-
kW-months/year
-
-
MMBtu
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$737
Cost:
$1,000
$719 8,985 $18 4 - - $719
8,985
kWh
$18
4
kW-months/year
-
-
MMBtu
09: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$179
Cost:
$280
$179 2,236 - - - - $179
2,236
kWh
-
-
kW-months/year
-
-
MMBtu
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$732
Cost:
$1,645
$664 8,299 $68 16 - - $664
8,299
kWh
$68
16
kW-months/year
-
-
MMBtu
11: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL Savings:
$5,980
Cost:
$15,100
$4,593 57,408 $1,388 331 - - $4,593
57,408
kWh
$1,388
331
kW-months/year
-
-
MMBtu
12: 2.5111 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS Savings:
$1,822
Cost:
$6,360
- - - - $1,822 230 -
-
kWh
-
-
kW-months/year
$1,822
230
MMBtu
13: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR Savings:
$5,934
Cost:
$24,500
$4,560 57,000 $1,374 328 - - $4,560
57,000
kWh
$1,374
328
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$29,730
Cost:
$59,301
$13,235 165,432 $3,199 764 $13,297 1,681 $13,235
165,432
kWh
$3,199
764
kW-months/year
$13,297
1,681
MMBtu
TOTAL IMPLEMENTED Savings:
$15,422
Cost:
$27,973
$6,402 80,019 $1,474 352 $7,546 954 $6,402
80,019
kWh
$1,474
352
kW-months/year
$7,546
954
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas