Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Lehigh University
Assessment Year 2016
Principal Product Printed Polyethylene Bags
NAICS 323111 - Commercial Printing (except Screen and Books)
SIC 2759 - Commercial Printing, Nec
Sales $50,000,000-$100,000,000
# of Employees 120
Plant Area (Sq.Ft.) 85,000
Annual Production 485,000,000 Units
Production Hrs. Annual 8,736
Location (State) PA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $381,789 6,521,237 kWh $0.06
Electricity Demand $44,703 11,477 kW-months/year $3.90
Electricity Fees $24,551 - $ -
Natural Gas $136,090 19,861 MMBtu $6.85
TOTAL ENERGY COSTS $587,133
RECOMMENDED SAVINGS* $18,565 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $16,980
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$4,742
Cost:
$1,000
$4,349 73,706 $393 101 - - - - $4,349
73,706
kWh
$393
101
kW-months/year
-
-
MMBtu
-
-
$
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,378
Cost:
$600
$2,192 37,147 $186 48 - - - - $2,192
37,147
kWh
$186
48
kW-months/year
-
-
MMBtu
-
-
$
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$7,795
Cost:
$2,750
- - - - $7,795 1,138 - - -
-
kWh
-
-
kW-months/year
$7,795
1,138
MMBtu
-
-
$
04: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$825
Cost:
$500
$825 13,978 - - - - - - $825
13,978
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,065
Cost:
$3,420
$1,744 29,563 $160 41 - - $161 - $1,744
29,563
kWh
$160
41
kW-months/year
-
-
MMBtu
$161
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$760
Cost:
$3,440
$643 10,903 $117 30 - - - - $643
10,903
kWh
$117
30
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$18,565
Cost:
$11,710
$9,753 165,297 $856 220 $7,795 1,138 $161 - $9,753
165,297
kWh
$856
220
kW-months/year
$7,795
1,138
MMBtu
$161
-
$
TOTAL IMPLEMENTED Savings:
$16,980
Cost:
$7,770
$8,285 140,416 $739 190 $7,795 1,138 $161 - $8,285
140,416
kWh
$739
190
kW-months/year
$7,795
1,138
MMBtu
$161
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes