IAC logo
IAC Assessment: LE0457
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: LE0457
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Lehigh University
Assessment Year 2018
Principal Product Laminated vinyl
NAICS 313320 - Fabric Coating Mills
SIC 2295 - Coated Fabrics, Not Rubberized
Sales $10,000,000-$50,000,000
# of Employees 45
Plant Area (Sq.Ft.) 160,000
Annual Production 26,941,227 Thousand Feet
Production Hrs. Annual 6,240
Location (State) PA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $213,445 3,022,125 kWh $0.07
Electricity Demand $30,496 7,569 kW-months/year $4.03
Electricity Fees $29,124 - $ -
Natural Gas $169,383 22,505 MMBtu $7.53
TOTAL ENERGY COSTS $442,448
RECOMMENDED SAVINGS* $53,862 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $19,471
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$9,554
Cost:
$25,157
$7,841 110,430 $1,713 425 - - $7,841
110,430
kWh
$1,713
425
kW-months/year
-
-
MMBtu
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$619
Cost:
$2,200
$534 7,524 $85 21 - - $534
7,524
kWh
$85
21
kW-months/year
-
-
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,771
Cost:
$10,041
$2,086 29,384 $685 170 - - $2,086
29,384
kWh
$685
170
kW-months/year
-
-
MMBtu
04: 2.1224 REPLACE BOILER Savings:
$33,772
Cost:
$150,000
- - - - $33,772 3,157 -
-
kWh
-
-
kW-months/year
$33,772
3,157
MMBtu
05: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$2,689
Cost:
$13,000
$2,405 33,869 $284 71 - - $2,405
33,869
kWh
$284
71
kW-months/year
-
-
MMBtu
06: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR Savings:
$4,457
Cost:
$36,000
$4,018 56,591 $439 109 - - $4,018
56,591
kWh
$439
109
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$53,862
Cost:
$236,398
$16,884 237,798 $3,206 796 $33,772 3,157 $16,884
237,798
kWh
$3,206
796
kW-months/year
$33,772
3,157
MMBtu
TOTAL IMPLEMENTED Savings:
$19,471
Cost:
$84,198
$16,350 230,274 $3,121 775 - - $16,350
230,274
kWh
$3,121
775
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas