Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Lehigh University
Assessment Year 2018
Principal Product Specialty Chemicals
NAICS 325998 - All Other Miscellaneous Chemical Product and Preparation Manufacturing
SIC 2899 - Chemical Preparations, Nec
Sales $10,000,000-$50,000,000
# of Employees 71
Plant Area (Sq.Ft.) 50,000
Annual Production 1,540,000 Pounds
Production Hrs. Annual 6,240
Location (State) PA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $251,012 3,857,525 kWh $0.07
Electricity Demand $64,123 11,284 kW-months/year $5.68
Electricity Fees $11,638 - $ -
Natural Gas $135,316 16,700 MMBtu $8.10
TOTAL ENERGY COSTS $462,089
RECOMMENDED SAVINGS* $134,847 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $45,655
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,239
Cost:
$70
$1,125 17,321 $114 20 - - $1,125
17,321
kWh
$114
20
kW-months/year
-
-
MMBtu
02: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$53,879
Cost:
$30,500
$31,686 487,472 $2,948 519 $19,245 2,376 $31,686
487,472
kWh
$2,948
519
kW-months/year
$19,245
2,376
MMBtu
03: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$6,825
Cost:
$7,525
$4,780 73,536 $2,045 360 - - $4,780
73,536
kWh
$2,045
360
kW-months/year
-
-
MMBtu
04: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$19,392
Cost:
$30,000
$17,887 275,184 $1,505 265 - - $17,887
275,184
kWh
$1,505
265
kW-months/year
-
-
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$22,792
Cost:
$85,052
$19,924 306,519 $2,868 505 - - $19,924
306,519
kWh
$2,868
505
kW-months/year
-
-
MMBtu
06: 2.1224 REPLACE BOILER Savings:
$9,096
Cost:
$35,000
- - - - $9,096 1,123 -
-
kWh
-
-
kW-months/year
$9,096
1,123
MMBtu
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$21,624
Cost:
$93,750
$19,307 297,024 $2,317 408 - - $19,307
297,024
kWh
$2,317
408
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$134,847
Cost:
$281,897
$94,709 1,457,056 $11,797 2,077 $28,341 3,499 $94,709
1,457,056
kWh
$11,797
2,077
kW-months/year
$28,341
3,499
MMBtu
TOTAL IMPLEMENTED Savings:
$45,655
Cost:
$178,872
$40,356 620,864 $5,299 933 - - $40,356
620,864
kWh
$5,299
933
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas