Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2021 |
Principal Product | Architectural Glass |
NAICS | 327211 - Flat Glass Manufacturing |
SIC | 3211 - Flat Glass |
Sales | $100,000,000-$500,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 1,400,000 |
Annual Production | 383,000 Thousand Feet |
Production Hrs. Annual | 8,736 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $5,787,619 | 125,907,600 | kWh | $0.05 |
Electricity Demand | $47,851 | 218,363 | kW-months/year | $0.22 |
Electricity Fees | $211,969 | - | $ | - |
Natural Gas | $6,523,175 | 2,818,720 | MMBtu | $2.31 |
TOTAL ENERGY COSTS | $12,570,614 | |||
RECOMMENDED SAVINGS* | $1,767,681 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $42,017 Cost: $17,100 |
$41,743 | 907,460 | $274 | 1,247 | - | - | - | - | - | - | - | - |
$41,743 907,460 kWh |
$274 1,247 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $47,926 Cost: $45,000 |
$47,613 | 1,035,061 | $313 | 1,422 | - | - | - | - | - | - | - | - |
$47,613 1,035,061 kWh |
$313 1,422 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $31,951 Cost: $30,000 |
$31,742 | 690,041 | $209 | 949 | - | - | - | - | - | - | - | - |
$31,742 690,041 kWh |
$209 949 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $19,170 Cost: $21,000 |
$19,045 | 414,025 | $125 | 569 | - | - | - | - | - | - | - | - |
$19,045 414,025 kWh |
$125 569 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $19,596 Cost: $33,000 |
$19,468 | 423,226 | $128 | 581 | - | - | - | - | - | - | - | - |
$19,468 423,226 kWh |
$128 581 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,899 Cost: $12,800 |
$4,867 | 105,805 | $32 | 145 | - | - | - | - | - | - | - | - |
$4,867 105,805 kWh |
$32 145 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $22,653 Cost: $100,000 |
$22,505 | 489,216 | $148 | 672 | - | - | - | - | - | - | - | - |
$22,505 489,216 kWh |
$148 672 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1224 REPLACE BOILER |
Savings: $334,294 Cost: $1,800,000 |
- | - | - | - | $294,294 | 127,400 | - | - | - | - | $40,000 | - |
- - kWh |
- - kW-months/year |
$294,294 127,400 MMBtu |
- - $ |
- - $ |
$40,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $1,245,175 Cost: $9,990,000 |
$721,655 | 15,688,152 | - | - | - | - | $627,520 | - | $(-104,000) | - | - | - |
$721,655 15,688,152 kWh |
- - kW-months/year |
- - MMBtu |
$627,520 - $ |
$(-104,000) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,767,681 Cost: $12,048,900 |
$908,638 | 19,752,986 | $1,229 | 5,585 | $294,294 | 127,400 | $627,520 | - | $(-104,000) | - | $40,000 | - | $908,638 19,752,986 kWh |
$1,229 5,585 kW-months/year |
$294,294 127,400 MMBtu |
$627,520 - $ |
$(-104,000) - $ |
$40,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost |