Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2022 |
Principal Product | Pallets |
NAICS | 321920 - Wood Container and Pallet Manufacturing |
SIC | 2448 - Wood Pallets And Skids |
Sales | $5,000,000-$10,000,000 |
# of Employees | 78 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 1,000,000 Units |
Production Hrs. Annual | 3,900 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $46,101 | 747,177 | kWh | $0.06 |
Electricity Demand | $14,907 | 3,741 | kW-months/year | $3.98 |
Electricity Fees | $7,548 | - | $ | - |
LPG | $61,031 | 3,565 | MMBtu | $17.12 |
TOTAL ENERGY COSTS | $129,587 | |||
RECOMMENDED SAVINGS* | $163,218 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,756 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Increase in Production | Electricity Usage | Electricity Demand | LPG | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $993 Cost: $150 |
$830 | 13,400 | $163 | 41 | - | - | - | - |
$830 13,400 kWh |
$163 41 kW-months/year |
- - MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $6,698 Cost: $5,000 |
$5,592 | 90,192 | $1,106 | 278 | - | - | - | - |
$5,592 90,192 kWh |
$1,106 278 kW-months/year |
- - MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $108,808 Cost: $250,000 |
$6,531 | 105,331 | $2,277 | 572 | - | - | $100,000 | - |
$6,531 105,331 kWh |
$2,277 572 kW-months/year |
- - MMBtu |
$100,000 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $763 Cost: $2,001 |
$648 | 10,448 | $115 | 29 | - | - | - | - |
$648 10,448 kWh |
$115 29 kW-months/year |
- - MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.6123 BURN WOOD BY-PRODUCTS FOR HEAT |
Savings: $41,476 Cost: $130,000 |
- | - | - | - | $41,476 | 2,469 | - | - |
- - kWh |
- - kW-months/year |
$41,476 2,469 MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,480 Cost: $20,000 |
$3,457 | 55,763 | $1,023 | 257 | - | - | - | - |
$3,457 55,763 kWh |
$1,023 257 kW-months/year |
- - MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $163,218 Cost: $407,151 |
$17,058 | 275,134 | $4,684 | 1,177 | $41,476 | 2,469 | $100,000 | - | $17,058 275,134 kWh |
$4,684 1,177 kW-months/year |
$41,476 2,469 MMBtu |
$100,000 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,756 Cost: $2,151 |
$1,478 | 23,848 | $278 | 70 | - | - | - | - | $1,478 23,848 kWh |
$278 70 kW-months/year |
- - MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Increase in Production | Electricity Usage | Electricity Demand | LPG | Increase in Production |