Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2025 |
Principal Product | Chemical mixing |
NAICS | 424690 - Other Chemical and Allied Products Merchant Wholesalers |
SIC | 5169 - Chemicals & Allied Products, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 238 |
Plant Area (Sq.Ft.) | 270,000 |
Annual Production | 88,504 Tons |
Production Hrs. Annual | 3,822 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $109,479 | 1,903,767 | kWh | $0.06 |
Electricity Demand | $20,342 | 4,042 | kW-months/year | $5.03 |
Electricity Fees | $28,181 | - | $ | - |
Natural Gas | $74,821 | 13,851 | MMBtu | $5.40 |
TOTAL ENERGY COSTS | $232,823 | |||
RECOMMENDED SAVINGS* | $190,376 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $27,784 Cost: - |
$784 | 13,529 | - | - | $27,000 | 5,000 | - | - |
$784 13,529 kWh |
- - kW-months/year |
$27,000 5,000 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $17,317 Cost: $2,200 |
$14,842 | 255,896 | $2,475 | 492 | - | - | - | - |
$14,842 255,896 kWh |
$2,475 492 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,395 Cost: $660 |
$1,194 | 20,592 | $201 | 40 | - | - | - | - |
$1,194 20,592 kWh |
$201 40 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $11,641 Cost: $25,639 |
$11,229 | 193,610 | $412 | 82 | - | - | - | - |
$11,229 193,610 kWh |
$412 82 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.9112 USE SOLAR HEAT TO HEAT WATER |
Savings: $132,239 Cost: $658,000 |
$48,474 | 598,450 | - | - | - | - | $83,765 | - |
$48,474 598,450 kWh |
- - kW-months/year |
- - MMBtu |
$83,765 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $190,376 Cost: $686,499 |
$76,523 | 1,082,077 | $3,088 | 614 | $27,000 | 5,000 | $83,765 | - | $76,523 1,082,077 kWh |
$3,088 614 kW-months/year |
$27,000 5,000 MMBtu |
$83,765 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost |