Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2025 |
Principal Product | Other Basic Inorganic Chemical Manufacturing |
NAICS | 325180 - Other Basic Inorganic Chemical Manufacturing |
SIC | 2899 - Chemical Preparations, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 81 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 90,000,000 Pounds |
Production Hrs. Annual | 3,120 |
Location (State) | MD |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $103,047 | 4,395,152 | kWh | $0.02 |
Electricity Demand | $79,860 | 10,525 | kW-months/year | $7.59 |
Electricity Fees | $3,787 | - | $ | - |
Natural Gas | $149,723 | 11,013 | MMBtu | $13.60 |
TOTAL ENERGY COSTS | $336,417 | |||
RECOMMENDED SAVINGS* | $140,994 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.651 INSTALL BACK-UP EQUIPMENT |
Savings: $125,769 Cost: $50,000 |
- | - | - | - | - | - | $125,769 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$125,769 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,428 Cost: $3,300 |
$4,423 | 192,394 | $2,005 | 264 | - | - | - | - |
$4,423 192,394 kWh |
$2,005 264 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $1,179 Cost: $800 |
$1,179 | 51,280 | - | - | - | - | - | - |
$1,179 51,280 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $651 Cost: $1,275 |
$651 | 28,305 | - | - | - | - | - | - |
$651 28,305 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $1,588 Cost: $5,000 |
$(-300) | (-13,034) | $(-137) | (-18) | $2,025 | 149 | - | - |
$(-300) (-13,034) kWh |
$(-137) (-18) kW-months/year |
$2,025 149 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,173 Cost: $4,403 |
$517 | 22,464 | $656 | 86 | - | - | - | - |
$517 22,464 kWh |
$656 86 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $4,206 Cost: $19,974 |
$3,074 | 133,674 | $1,132 | 149 | - | - | - | - |
$3,074 133,674 kWh |
$1,132 149 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $140,994 Cost: $84,752 |
$9,544 | 415,083 | $3,656 | 481 | $2,025 | 149 | $125,769 | - | $9,544 415,083 kWh |
$3,656 481 kW-months/year |
$2,025 149 MMBtu |
$125,769 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost |