Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2001 |
Principal Product | Offshore drilling completion equipment |
NAICS | n/a |
SIC | 3533 - Oil And Gas Field Machinery |
Sales | $10,000,000-$50,000,000 |
# of Employees | 94 |
Plant Area (Sq.Ft.) | 45,600 |
Annual Production | 20,000,000 Pounds |
Production Hrs. Annual | 5,200 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $193,878 | 2,506,650 | kWh | $0.08 |
Electricity Demand | $41,672 | 7,392 | kW-months/year | $5.64 |
Electricity Fees | $(-28,338) | - | $ | - |
Natural Gas | $7,004 | 598 | MMBtu | $11.71 |
TOTAL ENERGY COSTS | $253,031 | |||
RECOMMENDED SAVINGS* | $47,858 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $19,588 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $6,070 Cost: $8,640 |
- | - | $5,837 | 1,044 | $233 | - | - | - | - | - |
- - kWh |
$5,837 1,044 kW-months/year |
$233 - $ |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $6,866 Cost: $325 |
$4,854 | 67,392 | $1,748 | 311 | $264 | - | - | - | - | - |
$4,854 67,392 kWh |
$1,748 311 kW-months/year |
$264 - $ |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $5,657 Cost: $82 |
$4,450 | 61,776 | $989 | 176 | $218 | - | - | - | - | - |
$4,450 61,776 kWh |
$989 176 kW-months/year |
$218 - $ |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $441 Cost: $180 |
$424 | 5,887 | - | - | $17 | - | - | - | - | - |
$424 5,887 kWh |
- - kW-months/year |
$17 - $ |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $296 Cost: - |
- | - | - | - | $296 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$296 - $ |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $18,851 Cost: - |
- | - | - | - | - | - | - | - | $18,851 | 1,120 |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
$18,851 1,120 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4133 CLEAN FOULING FROM WATER LINES REGULARLY |
Savings: $9,677 Cost: $2,200 |
- | - | - | - | - | - | $9,677 | 81,200 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$9,677 81,200 Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $47,858 Cost: $11,427 |
$9,728 | 135,055 | $8,574 | 1,531 | $1,028 | - | $9,677 | 81,200 | $18,851 | 1,120 | $9,728 135,055 kWh |
$8,574 1,531 kW-months/year |
$1,028 - $ |
$9,677 81,200 Tgal |
$18,851 1,120 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $19,588 Cost: $180 |
$424 | 5,887 | - | - | $313 | - | - | - | $18,851 | 1,120 | $424 5,887 kWh |
- - kW-months/year |
$313 - $ |
- - Tgal |
$18,851 1,120 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) |