Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2001 |
Principal Product | Steel Fabrication |
NAICS | n/a |
SIC | 3433 - Heating Equipment, Except Electric |
Sales | $100,000,000-$500,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 79,000 |
Annual Production | 120 Pieces |
Production Hrs. Annual | 6,917 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $65,635 | 1,551,750 | kWh | $0.04 |
Electricity Demand | $45,730 | 5,775 | kW-months/year | $7.92 |
Electricity Fees | $4,148 | - | $ | - |
TOTAL ENERGY COSTS | $119,026 | |||
RECOMMENDED SAVINGS* | $26,655 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $24,797 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $605 Cost: $74 |
$416 | 51,057 | $166 | 22 | $23 | - | - | - | - | - |
$416 51,057 kWh |
$166 22 kW-months/year |
$23 - $ |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $9,873 Cost: $10,440 |
- | - | $9,493 | 1,257 | $380 | - | - | - | - | - |
- - kWh |
$9,493 1,257 kW-months/year |
$380 - $ |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,253 Cost: - |
$201 | 24,647 | $1,004 | 133 | $48 | - | - | - | - | - |
$201 24,647 kWh |
$1,004 133 kW-months/year |
$48 - $ |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $12,892 Cost: $2,400 |
$12,396 | 1,522,808 | - | - | $496 | - | - | - | - | - |
$12,396 1,522,808 kWh |
- - kW-months/year |
$496 - $ |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $552 Cost: - |
- | - | - | - | - | - | - | - | $552 | 1,200 |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
$552 1,200 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $1,480 Cost: - |
- | - | - | - | - | - | $1,480 | 893,550 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,480 893,550 Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $26,655 Cost: $12,914 |
$13,013 | 1,598,512 | $10,663 | 1,412 | $947 | - | $1,480 | 893,550 | $552 | 1,200 | $13,013 1,598,512 kWh |
$10,663 1,412 kW-months/year |
$947 - $ |
$1,480 893,550 Tgal |
$552 1,200 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $24,797 Cost: $12,840 |
$12,396 | 1,522,808 | $9,493 | 1,257 | $876 | - | $1,480 | 893,550 | $552 | 1,200 | $12,396 1,522,808 kWh |
$9,493 1,257 kW-months/year |
$876 - $ |
$1,480 893,550 Tgal |
$552 1,200 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) |