Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisiana, Lafayette
Assessment Year 2001
Principal Product Fabricated Pipe
NAICS n/a
SIC 3498 - Fabricated Pipe And Fittings
Sales $10,000,000-$50,000,000
# of Employees 45
Plant Area (Sq.Ft.) 54,000
Annual Production 100,000 Pieces
Production Hrs. Annual 2,600
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $132,928 1,389,600 kWh $0.10
Electricity Demand $55,964 9,958 kW-months/year $5.62
Electricity Fees $(-21,367) - $ -
Natural Gas $96,192 17,271 MMBtu $5.57
TOTAL ENERGY COSTS $263,717
RECOMMENDED SAVINGS* $40,660 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $21,150
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Solid Waste (non-haz) Electricity Usage Electricity Demand Electricity Fees Solid Waste (non-haz)
$ kWh $ kW-months/year $ $ $ lb
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$1,842
Cost:
-
$1,175 22,764 $596 106 $71 - - - $1,175
22,764
kWh
$596
106
kW-months/year
$71
-
$
-
-
lb
02: 2.7134 USE PHOTOCELL CONTROLS Savings:
$2,864
Cost:
$282
$2,017 28,454 $736 131 $111 - - - $2,017
28,454
kWh
$736
131
kW-months/year
$111
-
$
-
-
lb
03: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$16,646
Cost:
$15,900
- - $16,006 2,120 $640 - - - -
-
kWh
$16,006
2,120
kW-months/year
$640
-
$
-
-
lb
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$13,683
Cost:
$2,700
$13,136 185,569 - - $547 - - - $13,136
185,569
kWh
-
-
kW-months/year
$547
-
$
-
-
lb
05: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE Savings:
$5,625
Cost:
-
- - - - - - $5,625 262,000 -
-
kWh
-
-
kW-months/year
-
-
$
$5,625
262,000
lb
TOTAL RECOMMENDED Savings:
$40,660
Cost:
$18,882
$16,328 236,787 $17,338 2,357 $1,369 - $5,625 262,000 $16,328
236,787
kWh
$17,338
2,357
kW-months/year
$1,369
-
$
$5,625
262,000
lb
TOTAL IMPLEMENTED Savings:
$21,150
Cost:
$2,700
$14,311 208,333 $596 106 $618 - $5,625 262,000 $14,311
208,333
kWh
$596
106
kW-months/year
$618
-
$
$5,625
262,000
lb
Savings
Cost
$ kWh $ kW-months/year $ $ $ lb
Electricity Usage Electricity Demand Electricity Fees Solid Waste (non-haz) Electricity Usage Electricity Demand Electricity Fees Solid Waste (non-haz)