Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2001 |
Principal Product | Fabricated Pipe |
NAICS | n/a |
SIC | 3498 - Fabricated Pipe And Fittings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 45 |
Plant Area (Sq.Ft.) | 54,000 |
Annual Production | 100,000 Pieces |
Production Hrs. Annual | 2,600 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $132,928 | 1,389,600 | kWh | $0.10 |
Electricity Demand | $55,964 | 9,958 | kW-months/year | $5.62 |
Electricity Fees | $(-21,367) | - | $ | - |
Natural Gas | $96,192 | 17,271 | MMBtu | $5.57 |
TOTAL ENERGY COSTS | $263,717 | |||
RECOMMENDED SAVINGS* | $40,660 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $21,150 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,842 Cost: - |
$1,175 | 22,764 | $596 | 106 | $71 | - | - | - |
$1,175 22,764 kWh |
$596 106 kW-months/year |
$71 - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $2,864 Cost: $282 |
$2,017 | 28,454 | $736 | 131 | $111 | - | - | - |
$2,017 28,454 kWh |
$736 131 kW-months/year |
$111 - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $16,646 Cost: $15,900 |
- | - | $16,006 | 2,120 | $640 | - | - | - |
- - kWh |
$16,006 2,120 kW-months/year |
$640 - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $13,683 Cost: $2,700 |
$13,136 | 185,569 | - | - | $547 | - | - | - |
$13,136 185,569 kWh |
- - kW-months/year |
$547 - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $5,625 Cost: - |
- | - | - | - | - | - | $5,625 | 262,000 |
- - kWh |
- - kW-months/year |
- - $ |
$5,625 262,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $40,660 Cost: $18,882 |
$16,328 | 236,787 | $17,338 | 2,357 | $1,369 | - | $5,625 | 262,000 | $16,328 236,787 kWh |
$17,338 2,357 kW-months/year |
$1,369 - $ |
$5,625 262,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $21,150 Cost: $2,700 |
$14,311 | 208,333 | $596 | 106 | $618 | - | $5,625 | 262,000 | $14,311 208,333 kWh |
$596 106 kW-months/year |
$618 - $ |
$5,625 262,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) |