IAC logo
IAC Assessment: LL0120
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: LL0120
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisiana, Lafayette
Assessment Year 2001
Principal Product Nickel alloy and titanium alloy piping and tubing
NAICS n/a
SIC 3089 - Plastics Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 133
Plant Area (Sq.Ft.) 125,000
Annual Production 2,000 Thousand Feet
Production Hrs. Annual 7,488
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $654,061 9,640,294 kWh $0.07
Electricity Demand $3,863 23,155 kW-months/year $0.17
Electricity Fees $70,079 - $ -
Natural Gas $235,842 63,263 MMBtu $3.73
TOTAL ENERGY COSTS $1,002,278
RECOMMENDED SAVINGS* $404,294 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $173,750
#|Description Savings
Cost
Status Electricity Usage Electricity Fees Natural Gas Solid Waste (non-haz) Electricity Usage Electricity Fees Natural Gas Solid Waste (non-haz)
$ kWh $ $ $ MMBtu $ lb
01: 2.2511 INSULATE BARE EQUIPMENT Savings:
$165,697
Cost:
$5,304
$159,324 2,348,173 $6,373 - - - - - $159,324
2,348,173
kWh
$6,373
-
$
-
-
MMBtu
-
-
lb
02: 2.7134 USE PHOTOCELL CONTROLS Savings:
$8,053
Cost:
$110
$7,743 114,120 $310 - - - - - $7,743
114,120
kWh
$310
-
$
-
-
MMBtu
-
-
lb
03: 2.3412 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR Savings:
$205,089
Cost:
$425,809
$271,400 4,000,000 $7,888 - $(-74,199) (-18,404) - - $271,400
4,000,000
kWh
$7,888
-
$
$(-74,199)
(-18,404)
MMBtu
-
-
lb
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$13,925
Cost:
$7,125
- - - - $13,925 3,561 - - -
-
kWh
-
-
$
$13,925
3,561
MMBtu
-
-
lb
05: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE Savings:
$11,530
Cost:
-
- - - - - - $11,530 1,152 -
-
kWh
-
-
$
-
-
MMBtu
$11,530
1,152
lb
TOTAL RECOMMENDED Savings:
$404,294
Cost:
$438,348
$438,467 6,462,293 $14,571 - $(-60,274) (-14,843) $11,530 1,152 $438,467
6,462,293
kWh
$14,571
-
$
$(-60,274)
(-14,843)
MMBtu
$11,530
1,152
lb
TOTAL IMPLEMENTED Savings:
$173,750
Cost:
$5,414
$167,067 2,462,293 $6,683 - - - - - $167,067
2,462,293
kWh
$6,683
-
$
-
-
MMBtu
-
-
lb
Savings
Cost
$ kWh $ $ $ MMBtu $ lb
Electricity Usage Electricity Fees Natural Gas Solid Waste (non-haz) Electricity Usage Electricity Fees Natural Gas Solid Waste (non-haz)